7 MCM Parameters
7 - 39
At program editing and also entering even numbers, the system will
automatically add decimal point to even numbers.
532. In the milling mode, set the gap for drill to withdraw.
Format= . (Default= 2.000) unit:mm
533. Setting the test following count
Format= (Default= 0)
With use of parameter Item No.534
534. Testing the axial setting of the servo following error function
Format= (Default = 0)
Set the testing corresponding to the axis with Bit
Description:
When MCM534 1 and Bit0 = 1, test the X-axus.
When MCM534 2 and Bit1 = 1, test the Y-axis.
When MCM534 4 and Bit2 = 1, test the Z-axis.
When MCM534 8 and Bit3 = 1, test the A-axis.
When MCM534 16 and Bit4 = 1, test the B-axis.
When MCM534 32 and Bit5 = 1, test the C-axis.
When MCM534 64 and Bit6 = 1, test the U-axis.
When MCM534 128 and Bit7 = 1, test the V-axis.
When MCM534 256 and Bit8 = 1, test the W-axis.
When MCM534 511, i.e. Bit0 ~ Bit8= 1, then test X/Y/Z/A/B/C/U/V/W-axes at
the same time.
Caution: For HUST H6D/H9D controller, if the servo motor used is a voltage
command type, it is necessary to set testing the following error function ( not
applicable for the impulse command type).
The controller will compare the actual feedback difference of the servo motor
with the setting of the parameter Item No 533. If the controller detects that the
axis has been set beyond the range, the system will display an error message.
Example: When the parameter Item No 533= 4096, the parameter Item No
534=1, and
The actual motor following error
4096 (Parameter Item No 533), it will generate ERROR 02 X
535. Controller ID number
Control connection of multiple units with PC. Currently, the function is reserved.