FluidControl Unit
FCU 2110 - 5
FCU 2210 - 5
Operating and Maintenance Instructions
Ed. 1.1/12.2000

Table of Contents

Questions and Answers

  • R
    Ricardo ArmstrongSep 3, 2025
    What does 'use power supply' mean on my HYDAC International Control Unit?
    • T
      Tiffany MackSep 3, 2025
      The message 'use power supply' on your HYDAC International Control Unit indicates that the rechargeable batteries are discharged. You should charge the batteries with the line adapter for approximately 11 hours. You can still perform measurements with the line adapter connected.
  • J
    John HoltSep 18, 2025
    What does 'Calibration defect' mean on HYDAC International Control Unit?
    • L
      lrichardsonSep 18, 2025
      The message 'Calibration defect' on your HYDAC International Control Unit means that internal calibration data in EEPROM are lost due to a disturbance. Ship FCU to HYDAC for repair in any case.
  • W
    wcampbellSep 16, 2025
    What does 'Device ID defect' mean on HYDAC International Control Unit?
    • D
      Danielle AlvarezSep 16, 2025
      The message 'Device ID defect' on your HYDAC International Control Unit indicates that internal designations in EEPROM are lost due to a disturbance. This is not a critical error, as these designations do not affect the FCU's proper function. You may ship the FCU to HYDAC for repair eventually.
  • L
    Lisa GarciaSep 14, 2025
    What does 'Internal printer not ready' mean on HYDAC International Control Unit?
    • D
      Danny BrownSep 14, 2025
      If the HYDAC International Control Unit displays 'Internal printer not ready', it could be due to an empty paper roll or a damaged printer. Replace the paper roll with a new one. If the problem persists, ship the FCU to HYDAC for repair.
  • J
    Jeffrey CruzSep 12, 2025
    What to do if HYDAC International Control Unit displays 'ext. Input activated'?
    • S
      Sarah TravisSep 12, 2025
      If the HYDAC International Control Unit displays 'ext. Input activated' (specifically with the OF5C filtration unit), it means the clogging indicator of the OF5C is activated, indicating that the OF5C filter is clogged. Replace the OF5C filter element.
  • S
    Sean SextonSep 12, 2025
    What does 'Filter contaminated' mean on HYDAC International Control Unit?
    • T
      Teresa YatesSep 12, 2025
      The message 'Filter contaminated' on your HYDAC International Control Unit indicates that the internal protection filter for the flow control valve of the FCU is clogged. Replace the FCU filter element.
  • S
    Stephen ChaneySep 9, 2025
    What does 'no logs stored !!' mean on HYDAC International Control Unit?
    • V
      Vickie MossSep 9, 2025
      The message 'no logs stored !!' on the HYDAC International Control Unit indicates that you've attempted to print logs, but the memory is empty. To resolve this, perform new measurements.
  • K
    kimberly01Sep 7, 2025
    What does 'not enough points' mean on HYDAC International Control Unit?
    • K
      Kristi FranklinSep 7, 2025
      The message 'not enough points' on the HYDAC International Control Unit means that you've tried to print a graph, but the selected log doesn't have enough measurement values (at least 3) to display a graph. Instead, print the log as a list.
  • M
    Melinda BrownSep 5, 2025
    What does 'Invalid parameter' mean on HYDAC International Control Unit and how to fix it?
    • N
      Nicholas RoachSep 5, 2025
      The 'Invalid parameter' message on the HYDAC International Control Unit means you've entered a value outside the allowed range (e.g., ISO 40). To fix this, check the allowed value range using the arrow keys +? and -?. Scroll above the maximum values to automatically display the minimum value. This process works both forward and backward.
  • J
    john78Aug 20, 2025
    What to do if HYDAC International Control Unit displays 'Check parameters Defective parameter: no. XX'?
    • J
      Jeff DanielAug 21, 2025
      If the self-monitoring function of the FCU detects a checksum error at one or more parameters, likely due to a strong electromagnetic disturbance, you should: * Adjust all parameters again using the FCU keypad. * Alternatively, download all parameters again using the FCUDESK PC software package.