EasyManua.ls Logo

Hydro Control HC-D3M Series - Page 12

Hydro Control HC-D3M Series
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TYPICAL CURVES - KENNLINIEN
48
HCD3M-04
HC-D3M
11
Sectional Valve - WEGEVENTIL IN SEKTIONSBAUWEISE
Direct relief valve curve Kennlinie des Druckbegrenzungsventils
Kennlinie des vorgesteuerten
Druckbegrenzungsventils
Pilot operated relief valve curve
Kennlinie des
Sekundärdruckbegrenzungsventils
Antishock valve curve
0
50
100
150
200
250
300
350
10 20 30 40 55
Qp
l/min
US-GPM
2.6 5.3 7.9 10.6 14.5
0
0
Δp
bar
psi
0
725
1450
2175
2900
3625
4350
5075
50
13.2
Setting ranges - Einstellbereich
(A) = 20/100 (bei max. Volumenstrom - at full flow)
10-A / 80-A (bei min. Volumenstrom - at min. flow)
(B) = 101/220 (bei max. Volumenstrom - at full flow)
81-A / 180-A (bei min. Volumenstrom - at min. flow)
(C) = 221/350 (bei max. Volumenstrom - at full flow)
181-A / 350-A (bei min. Volumenstrom - at min. flow)
0
50
100
150
200
250
300
350
10 20 30 40 55
Qp
l/min
US-GPM
2.6 5.3 7.9 10.6 14.5
0
0
Δp
bar
psi
0
725
1450
2175
2900
3625
4350
5075
Setting range - Einstellbereich
(A) = 30 / 350 (bar)
50
13.2
0
50
100
150
200
250
300
350
10 20 30 40 55
Qp
l/min
US-GPM
2.6 5.3 7.9 10.6 14.5
0
0
Δp
bar
psi
0
725
1450
2175
2900
3625
4350
5075
Setting ranges - Einstellbereich
(A) = 30 / 110 (bar)
(B) = 111 / 150 (bar)
(C) = 151 / 200 (bar)
(D) = 201 / 250 (bar)
(E) = 251 / 350 (bar)
50
13.2
Kennlinie des kombinierten VentilsCombined relief valve curve
0
50
100
150
200
250
300
350
10 20 30 40 55
Qp
l/min
US-GPM
2.6 5.3 7.9 10.6 14.5
0
0
Δp
bar
psi
0
725
1450
2175
2900
3625
4350
5075
50
13.2
Setting ranges - Einstellbereich
(A) = 20/60 (bei max. Volumenstrom - at full flow)
10-A / 40-A (bei min. Volumenstrom - at min. flow)
(B) = 61/100 (bei max. Volumenstrom - at full flow)
41-A / 80-A (bei min. Volumenstrom - at min. flow)
(C) = 101/220 (bei max. Volumenstrom - at full flow)
81-A / 180-A (bei min. Volumenstrom - at min. flow)
(D) = 221/350 (bei max. Volumenstrom - at full flow)
181-A / 350-A (bei min. Volumenstrom - at min. flow)