Installation & Maintenance Manual

Questions and Answers

  • S
    sharpjohnJul 27, 2025
    Why is the product flow rate low in my Hydro-Logic Purification Systems EVOLUTION-RO1000?
    • R
      royfosterJul 27, 2025
      A low product flow rate in your Hydro-Logic Purification Systems Water Filtration Systems can stem from several causes. It could be due to low driving pressure; in this case, increase the feed pressure, consider using a pump if you're in a low-pressure area, shorten tubing to reduce flow restrictions, or use wider tubing for longer distances. Alternatively, low water temperature or high total dissolved solids (TDS) might be the issue; increase the feed water temperature or pressure to compensate. A plugged prefilter can also be responsible, so replace it, and for non-chlorinated applications, think about using a sediment prefilter. If the RO membrane is scaled or fouled, replacing the membranes is the solution. Lastly, check for any leaks or kinks in the product line and repair them.
  • A
    Ashley AvilaAug 4, 2025
    What to do if concentrate water runs to drain after faucet shut off in Hydro-Logic Purification Systems Water Filtration Systems?
    • J
      John CruzAug 4, 2025
      If concentrate water continues to run to the drain after you shut off the faucet in your Hydro-Logic Purification Systems Water Filtration Systems, there are a couple of potential reasons. First, a plugged prefilter could be the culprit; replace the plugged prefilter, and consider using a sediment prefilter if you have non-chlorinated applications. Another possibility is a leak in the product line; find and repair any leaks. Installing a pressure gauge in the product line can help you identify a product pressure leak.
  • M
    marshallrebekahNov 13, 2025
    How to fix poor product water quality in Hydro-Logic Purification Systems EVOLUTION-RO1000 Water Filtration Systems?
    • M
      Matthew JuarezNov 13, 2025
      Poor product water quality in your Hydro-Logic Purification Systems Water Filtration Systems can arise from several factors. If the water sample was taken during system flush, retake the sample after three minutes of continuous operation. Another cause may be low driving pressure; increase the feed pressure, think about a pump for low pressure locations, shorten tubing to decrease flow restriction, or use a larger tubing diameter for longer runs. A plugged pre-filter could also be the reason; replace it, and consider a sediment prefilter for non-chlorinated applications. If the RO membrane is scaled, fouled, or damaged, replace the RO membranes. Finally, damaged membrane stem o-rings during installation can cause this; replace both o-rings on the membrane stem and lubricate them properly b...

Summary

SAFETY GUIDES

THE BASIC REVERSE OSMOSIS SYSTEM

BEFORE INSTALLING THE RO SYSTEM

Key considerations before starting the installation process for optimal performance.

THE BASIC REVERSE OSMOSIS SYSTEM cont.

LOCATION OF SYSTEM

Guidelines for selecting an appropriate installation site for the RO system.

INSTALLATION

Install Cold Water Supply Fitting

Instructions for connecting the cold water supply to the system.

Install Optional Drain Adapter

Procedure for connecting the drain line to an appropriate location.

Put System into Operation

Steps to start and initially operate the RO system.

INSTALLATION cont.

Make Tubing Connections

Connects the various tubing lines to the system components.

Install RO Assembly

Positions and connects the main RO unit components.

INSTALLATION cont.

Recommended Placement Positions

Options for positioning the RO assembly for optimal function.

Connection Lubrication

Guidelines for lubricating O-rings and contact surfaces for assembly.

INSTALLATION cont.

System Startup

Procedures for starting the system, checking for leaks, and flushing.

TO CARE FOR THE RO SYSTEM

REPLACEMENT OF PRE-FILTER

Information on replacing the carbon pre-filter based on usage.

REPLACEMENT OF RO MEMBRANE ELEMENTS

Guidelines for replacing RO membrane elements based on quality and time.

REPLACEMENT OF THE PRE-FILTER, AND RO MEMBRANE ELEMENTS

Detailed steps for replacing both pre-filter and membrane elements.

REPLACEMENT OF THE PRE-FILTER, AND RO MEMBRANE ELEMENTS cont.

Sanitize the system

Steps to sanitize the system after filter or membrane replacement.

Install pre-filter

Instructions for installing the new pre-filter element.

Performance Specifications

Dimensions

TROUBLESHOOTING

Low product flow rate

Identifies causes and solutions for reduced product water flow.

Concentrate water runs to drain after faucet shut off

Addresses issues where drain water continues to flow after use.

Poor product water quality

Solutions for problems related to the quality of purified water.