Performance Specifications
Minimum and Maximum Operating Conditions
Condition Minimum Maximum
Inlet Pressure 40 psi (2.76 bar) 80 psi (5.52 bar)
Inlet Temperature 40°F (4.44°C) 100°F (37.78°C)
Inlet TDS 50 mg/L 2,000 mg/L
Inlet Hardness 0 mg/L (0 grain) 171 mg/L (10 grain)
Inlet Chlorine 0 mg/L 1.0 mg/L
Inlet Iron 0 mg/L 0.1 mg/L
Inlet Manganese 0 mg/L 0.05 mg/L
Inlet pH 4 10
Inlet Turbidity 0 1 NTU