EasyManua.ls Logo

Hydrofarm ACTIVE AQUA AACH50 - User Manual

Hydrofarm ACTIVE AQUA AACH50
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTRUCTIONS
WATER CHILLERS
AACH10 AACH25
AACH50 AACH100

Questions and Answers

Summary

AACH10 CHILLER: 1;10 HP (13-50 GALLON)

AACH10 PERFORMANCE CURVE

Performance data for AACH10 chiller under specific ambient and reservoir conditions.

AACH10 SPECIFICATIONS

Detailed technical specifications for the AACH10 chiller model.

AACH25 CHILLER: 1;4 HP (26-80 GALLON)

AACH25 PERFORMANCE CURVE

Performance data for AACH25 chiller under specific ambient and reservoir conditions.

AACH25 SPECIFICATIONS

Detailed technical specifications for the AACH25 chiller model.

AACH50 CHILLER: 1;2 HP (52-132 GALLON)

AACH50 PERFORMANCE CURVE

Performance data for AACH50 chiller under specific ambient and reservoir conditions.

AACH50 SPECIFICATIONS

Detailed technical specifications for the AACH50 chiller model.

AACH100 CHILLER: 1 HP (80-250 GALLON)

AACH100 PERFORMANCE CURVE

Performance data for AACH100 chiller under specific ambient and reservoir conditions.

AACH100 SPECIFICATIONS

Detailed technical specifications for the AACH100 chiller model.

General Information

Complete Parts List

List of parts included with all Active Aqua chiller models.

Circuit Diagram

Schematic diagram illustrating the chiller's electrical circuit.

Features

Key features and benefits of the Active Aqua chiller series.

Introduction and Safety

Introduction

Overview of the Active Aqua Series Chiller and its benefits.

Suggestions for Safe Operation

Guidelines for safe usage and understanding of safety symbols.

Terms and Symbols

Explanation of hazard levels, terms, and symbols used in the manual.

Where to Install

Recommendations for proper placement and installation environment.

Installation and Operation

Installation Guidelines

Detailed instructions for positioning and setting up the chiller unit.

Assembly Instructions

Step-by-step guide for connecting tubing and setting up the system.

Temperature Settings and Controls

Operation Notes

Important notes regarding powering on and operating the chiller.

Warnings

Critical safety warnings for chiller operation.

Setting the Temperature

Procedure for adjusting and setting the desired water temperature.

Temperature Display

Understanding the chiller's temperature display indicators.

Maintenance and Troubleshooting

Compressor Operation

Explanation of how the compressor functions and its protection modes.

Error Codes

Information on identifying and resolving error codes displayed by the chiller.

Cleaning and Maintenance

Procedure for flushing and cleaning the internal components of the chiller.

Filter Maintenance and Troubleshooting

Air Filter Maintenance Procedure

Recommended steps for regular maintenance of the air filter.

Troubleshooting Guide

Common symptoms, causes, and solutions for chiller issues.

Warranty Information

Limited Warranty

Details of the chiller's one-year limited warranty terms and conditions.

Garantie Limitée

French translation of the limited warranty for the chiller.

Garantía Limitada

Spanish translation of the limited warranty for the chiller.

Summary

AACH10 CHILLER: 1;10 HP (13-50 GALLON)

AACH10 PERFORMANCE CURVE

Performance data for AACH10 chiller under specific ambient and reservoir conditions.

AACH10 SPECIFICATIONS

Detailed technical specifications for the AACH10 chiller model.

AACH25 CHILLER: 1;4 HP (26-80 GALLON)

AACH25 PERFORMANCE CURVE

Performance data for AACH25 chiller under specific ambient and reservoir conditions.

AACH25 SPECIFICATIONS

Detailed technical specifications for the AACH25 chiller model.

AACH50 CHILLER: 1;2 HP (52-132 GALLON)

AACH50 PERFORMANCE CURVE

Performance data for AACH50 chiller under specific ambient and reservoir conditions.

AACH50 SPECIFICATIONS

Detailed technical specifications for the AACH50 chiller model.

AACH100 CHILLER: 1 HP (80-250 GALLON)

AACH100 PERFORMANCE CURVE

Performance data for AACH100 chiller under specific ambient and reservoir conditions.

AACH100 SPECIFICATIONS

Detailed technical specifications for the AACH100 chiller model.

General Information

Complete Parts List

List of parts included with all Active Aqua chiller models.

Circuit Diagram

Schematic diagram illustrating the chiller's electrical circuit.

Features

Key features and benefits of the Active Aqua chiller series.

Introduction and Safety

Introduction

Overview of the Active Aqua Series Chiller and its benefits.

Suggestions for Safe Operation

Guidelines for safe usage and understanding of safety symbols.

Terms and Symbols

Explanation of hazard levels, terms, and symbols used in the manual.

Where to Install

Recommendations for proper placement and installation environment.

Installation and Operation

Installation Guidelines

Detailed instructions for positioning and setting up the chiller unit.

Assembly Instructions

Step-by-step guide for connecting tubing and setting up the system.

Temperature Settings and Controls

Operation Notes

Important notes regarding powering on and operating the chiller.

Warnings

Critical safety warnings for chiller operation.

Setting the Temperature

Procedure for adjusting and setting the desired water temperature.

Temperature Display

Understanding the chiller's temperature display indicators.

Maintenance and Troubleshooting

Compressor Operation

Explanation of how the compressor functions and its protection modes.

Error Codes

Information on identifying and resolving error codes displayed by the chiller.

Cleaning and Maintenance

Procedure for flushing and cleaning the internal components of the chiller.

Filter Maintenance and Troubleshooting

Air Filter Maintenance Procedure

Recommended steps for regular maintenance of the air filter.

Troubleshooting Guide

Common symptoms, causes, and solutions for chiller issues.

Warranty Information

Limited Warranty

Details of the chiller's one-year limited warranty terms and conditions.

Garantie Limitée

French translation of the limited warranty for the chiller.

Garantía Limitada

Spanish translation of the limited warranty for the chiller.

Hydrofarm ACTIVE AQUA AACH50 Specifications

General IconGeneral
ModelAACH50
TypeChiller
Cooling Capacity1/2 HP
Horsepower1/2 HP
Voltage115V
Frequency60Hz
RefrigerantR134a
Dimensions15 x 11 x 13 inches
Weight24 lbs

Related product manuals