DELIVERY, UNPACKING
AND SETUP
INSTRUCTIONS
PH 727-536-5566 Ext 1014
Fax 727-536-6633
salessupportteam@hydromassage.com
15395 Roosevelt Blvd.
Clearwater FL. 33760
www.hydromassage .com
Class I, Type B, IPXO, Equipment
Revised Jan 15, 2021
Water Requirements: 12 gallons of DISTILLED water.
Specications
Model HM200
Demensions: Length 91” Width 32” Height 46”
Weight: 285lbs w/o water / 370lbs with water
Requires a doorway larger than 32” to the installation room
Question and Answer IconNeed help?

Do you have a question about the HydroMassage HM200 and is the answer not in the manual?

Overview

The provided document is a delivery, unpacking, and setup instruction manual for a HydroMassage® unit, specifically model HM200.

Function Description

The HydroMassage® unit is a Class I, Type B, IPXO equipment designed to provide a massage experience using water. The unit is a lounge-style device where users lie down to receive the massage. It requires distilled water for operation and features a touchscreen for control.

Important Technical Specifications

  • Model: HM200
  • Dimensions: Length 91", Width 32", Height 46"
  • Weight: 285 lbs without water / 370 lbs with water
  • Water Requirements: 12 gallons of DISTILLED water
  • Power: 220 volt power cord
  • Doorway Requirement: Requires a doorway larger than 32" for installation.
  • Equipment Classification: Class I, Type B, IPXO

Usage Features

  • Touchscreen Control: The unit is operated via a touchscreen interface.
  • Massage Session Initiation: Users press a "START" button on the touchscreen to begin a massage session.
  • Pressure Adjustment: Massage pressure can be adjusted from levels 1-10.
  • Temperature Monitoring: The unit monitors water temperature. A "Water Temp Cold" error will appear if the water is below 70°F. For optimal operation, the temperature should be raised above 72°F.
  • Right-Hand Touchscreen Installation (Optional): The touchscreen can be optionally installed on the right-hand side for user preference, requiring specific steps involving a 7/16" wrench and Phillips screwdriver to reorient the bracket.

Maintenance Features

  • Panel Access: The unit's design allows for the removal of back, foot, and side panels for access during unpacking, setup, and potentially maintenance. These panels are secured with screws and flat bar knobs.
  • Water Filling: The unit has a designated fill spout and fill port for adding 12 gallons of distilled water and water treatment.
  • Pump Union Check: Before adding water, users are instructed to manually check and tighten two pump unions by turning them clockwise.
  • Flat Bar Knob Check: All 32 flat bar knobs around the top edge of the lounge must be securely tightened before adding water.
  • Leak Detection: During the initial test run, users are instructed to continuously check for leaks while the unit is operating.
  • Water Warming Procedure: If the water temperature is below 70°F, the instructions suggest raising the pressure level to 10 and running the unit for 20-30 minutes (with someone lying on the unit) to warm the water to above 72°F.
  • Technical Support: For any installation issues, HydroMassage® technical support can be contacted via email (salessupportteam@hydromassage.com or support@hydromassage.com) or phone (727-536-5566 Ext 1014, option 1).
  • Documentation: Complete maintenance documentation and resources are available on the HydroMassage® website (www.hydromassage.com or www.myhydromassage.com).

Unpacking and Setup Process Highlights

The manual details a step-by-step process for unpacking and setting up the unit, including:

  • Tools Needed: Tin-snips or scissors, Phillips #3 screwdriver, Rachet with 7/16" socket, 7/16" wrench.
  • Cautionary Notes: Emphasizes caution when removing plastic wrap to avoid scratching the unit, and recommends using two people for moving the unit to prevent injury and floor damage.
  • Panel Removal and Reinstallation: Detailed instructions for removing and reinstalling all exterior panels (back, foot, side, and base panels) using screws and flat bar knobs. It's important to place all removed panels and thumb screws in a secure location, finished side up.
  • Securing to Skid: The unit is secured to a plywood skid with four lag bolts that need to be removed during unpacking.
  • Moving the Unit: Recommends placing the unit on a 4-wheel dolly for movement.
  • Wire Harness and Cable Connections: Instructions for locating and connecting the USB cable and power connectors under the tank.
  • Initial Test Run: After setup, the unit must be plugged into a 220-volt outlet, and an initial test run performed to check for leaks and ensure proper operation, including water temperature.
  • Customer Acceptance: Before leaving the installation site, it is crucial to ensure all panels are secured with screws, all packing material is removed, and customer acceptance is signed.