EasyManua.ls Logo

HydroStat 3250-Plus User Manual

HydroStat 3250-Plus
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
83 Water Street New Haven, CT 06511 Phone (203) 776-0473 FAX (203) 773-1019 www.hydrolevel.com
MODEL 3250-Plus
Temp Limit / LWCO Control
with Thermal Targeting
for Water Boilers
120 VAC Operating Voltage
PATENT NO. 7,891,572
WARNING
Electrical shock hazard. To prevent electrical shock, death or
equipment damage, disconnect power supply before
installing or servicing control. Only qualified personnel may install or service this control in
accordance with local codes and ordinances. Read instructions completely before proceeding.
CAUTION
To prevent serious
burns, boiler
should be thoroughly cooled before installing or
servicing control.
WARNING
Frozen pipes/water damage. Central heating systems are prone to shut down as a result of power or fuel outages,
safety related fault conditions or equipment failure. Installation of freeze protection monitoring or other precautions
is recommended for unattended dwellings in climates subject to sustain below-freezing temperatures.
Three Function
Design
Temperature Limit Control
Designed for cold start and tankless
coil boilers.
Low Water Cut-Off
Provides protection against potentially
dangerous low water conditions
when installed with the Hydrolevel
Electro-Well™ (see page 2 for details).
Boiler Reset Control
Thermal Targeting On-board micro-
processor adjusts boiler temperature
based on heating demand.
Outdoor Reset Ready Compatible with
Hydrolevel OS-100 Outdoor Sensor Kit
(sold separately) for outdoor reset and
warm weather shut-down functionality.
INSTALLATION INSTRUCTIONS
and OPERATING MANUAL
Saves Fuel Features Thermal Targeting™ technology and
Thermal Pre-Purge capability
Outdoor Reset Ready Provides Outdoor Reset and Warm Weather
Shut-Down capability with the addition of Hydrolevel OS-100 Outdoor
Sensor Kit (sold separately)
Universal Design Replaces common cold-start and triple-action
Aquastats*
Operating Indicators LEDs, Dynamic Display and Test Button provide
continual and on-demand status checks
Prioritizes Domestic Hot Water Gives priority to low limit setting or to
calls from indirect water heater
Reduces Condensation Holds circulator off until boiler reaches 125°F
*Aquastat is a registered trademark of Honeywell International, Inc.
HydroStat 3250-Plus Instructions: HydroStat Instructions.8pg 11/14/13 3:43 PM Page 1
Question and Answer IconNeed help?

Do you have a question about the HydroStat 3250-Plus and is the answer not in the manual?

HydroStat 3250-Plus Specifications

Power IconPower
input voltage120 VAC, 60 HZ
Operating Environment IconOperating Environment
operating range – low limitOff or 110°F (43°C) - 200°F (93°C)
operating range – high limit100°F (38°C) - 220°F (104°C)
operating range – differentialsAutomatic
Electrical IconElectrical
burner contacts7.4 FLA, 44.4 LRA@120 VAC
circulator contacts5.8 FLA, 34.8 LRA@120 VAC
thermostat heat anticipator setting0.2A

Summary

Installation and Operation Manual

Three Function Design

Mounting the Control

Wiring Overview

Wiring Diagrams: Heating Only & Indirect Systems

Heating Only System Wiring

Wiring for single/multiple circulators without indirect water heaters.

Heating & Indirect Water Heater Wiring

Wiring for systems with indirect water heaters, single/multiple circulators.

Wiring Diagrams: Indirect System Details

Multiple Circulator Wiring with Priority Zone

Diagram for multiple circulators with priority zone control.

Single Circulator Wiring with Zone Valves

Diagram for single circulator with zone valves and indirect water heater.

Wiring Diagrams: Indirect System Details Continued

Multiple Circulator Wiring: Three Zone Relay

Diagram for multiple circulators using a three zone switch relay.

Setting the Control

Setting the High Limit Temperature

Instructions for adjusting the maximum operating temperature of the boiler.

Setting the Low Limit Temperature

Guidance on setting the minimum temperature for tankless coils or domestic hot water.

Setting the Economy Feature

How to configure the fuel-saving feature based on the number of heating zones.

Setting the Zone/Indirect Switch

Configuration for prioritizing indirect water heater calls over space heating.

How Thermal Targeting Works

LED Legend and Test/Settings Button

Troubleshooting

Troubleshooting Flow Chart: Burner Will Not Fire

Troubleshooting Flow Chart: Burner Will Not Shut Down

Electro-Well™ Models

Specifications