Fault code is shown as 01,
02, 03, 04, 05, 11, 12, 13 and
41 on LCD display and alarm
is continuously Beeping.
A UPS internal fault has
occurred. There are two possible
results:
1. The load is still supplied, but
directly from AC power via
bypass.
2. The load is no longer supplied
by power.
Battery backup time is
shorter than nominal value
Batteries are not fully charged
Charge the batteries for at
least 5 hours and then
check capacity. If the
problem still persists,
consult your dealer.
Contact your dealer to
replace the battery.
UPS Backup is proper, but
remaining time Indication on
display is not proper
Battery Group number setting is
wrong
Please refer Battery Group
number setting, and follow
steps.
Contact iBall Support team
/ Nearest iBall Service
Centre.
Fault code is shown as 05 on
LCD display. At the same
time, alarm is continuously
Beeping and output is cut off.
A UPS internal fault has occurred
and BUS is short circuited.
Consult your dealer. If the
UPS power is on again
before repair, the DC/DC
mosfet will damage.
5. Storage and Maintenance
Operation
The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at
25°C ambient temperature) has been exceeded, the batteries must be replaced. In this
case, please contact your dealer.
Storage
Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry
location. During storage, recharge the battery in accordance with the following table:
Be sure to deliver the spent battery to a recycling facility or ship it to your dealer
in the replacement battery packing material.