AHU Series Quick Reference Installation Guide
QS002 R1 Quick Reference Installaon Guide - AHU
Wiring (Manual secon 2.6 Electrical Connecons)
Default Sengs
(Manual secon 3.2 Default Fan Speed Sengs)
Conguraon with IBCconnect app (cont.)
Checklist
All AHU units comes set with the following default factory
sengs. The free IBCconnect app allows for congurang custom
sengs.
See reverse for a full page wiring diagram. See manual for
detailed wiring instrucons.
AHU Fan Speed Operaon
W1 Heang stage 1 = 600
CFM
Range 300-800
W2 Heang stage 2 = 800
CFM
Range 300-1000 (must be ≥
than heang stage 1)
Y1 Cooling stage 1 = 700
CFM
Range 300-800
Y2 Cooling stage = 1000
CFM
Range 300-1000 (must be ≥
than cooling stage 1)
G Fan on speed = 400
CFM
Range 150-1000
Electrical connecons
Ensure the power supply is 120V 15A circuit
☐
Check all electrical and thermostat connecons to ensure
they are correct and ght
☐
Thermostat is in a suitable locaon.
☐
Water connecons
All connecons are pressure-tested and leak-free.
☐
All piping ushed to ensure all air is removed
☐
Check valve installed, external pump is owing in the
correct direcon
☐
Boiler/water heater properly installed and safe to operate
☐
Ducng connecons
All connecons pressure-tested and leak-free.
☐
Ducts sized correctly and joints sealed.
☐
Air supply air dampers and registers are opened.
☐
Inspect lter, return air ducng, and registers.
☐
Water temperature is sucient for the space’s heang
requirements.
☐
Conguraon with IBCconnect app
(Manual secon 3.3 Operang the Unit with a Mobile App)
1. Scan the respecve QR codes above, or search for
“IBCconnect” (one word) on the Google Play or Apple App
store and tap Install.
2. Connect your device to the AHU.
Depending on your device, follow either the Android or
Apple instrucons below.
Android
1. Open the IBCconnect app. If the WiFi connecon is not
displayed as IBC-AHU, tap the WIFI SETTINGS buon.
2. Select IBC-AHU-xxxxx (where “xxxxx” is the controller serial
number)
3. Enter 1234567890 when prompted for a password the
rst me you connect.
4. With the AHU cover o, the LEDs on the circuit board will
start blinking simultaneously in an ON-OFF-ON-OFF paern
when connected.
5. Tap the device’s back buon to return to the app, then tap
GET STARTED to access the Home page, where you can start
adjusng sengs.
Default Sengs - Basic
Heang Mode 1 stage
Cooling Mode 2 stage
Boiler Heang 1 stage and 2 stage
Temperature °F
Pump Enable On
Tankless Mode On
Apple
You need to rst change some app sengs aer installaon. This
may vary depending on device and iOS version.
1. In the main iPhone Sengs, select Cellular.
2. Scroll down to IBCconnect under Cellular Data, and set to
O.
3. Navigate to the device’s Wi-Fi Sengs
4. Locate and select “IBC-AHU-xxxxx” on the list of available
networks, where “xxxxx” is the controller’s serial number.
5. Enter 1234567890 when prompted for a password the
rst me you connect.
6. With the AHU cover o, the LEDs on the circuit board will
start blinking simultaneously in an ON-OFF-ON-OFF paern
when connected.
7. Exit the Sengs screen and open the IBCconnect app.
8. The landing page should display “IBC-AHU-xxxxx”
9. Tap GET STARTED to access the Home page, where you can
start adjusng sengs.
Programming the air handling unit with the app
The IBC factory pre-programs the name of the model (AHU 800,
AHU 1200 or AHU 1600) in the appliance. However, you will need
to use the app to set the heang and cooling mode and to change
default sengs.
To set the mode using the IBCconnect app:
1. Tap (menu), and select Basic Sengs.
2. Set the Heat Mode and Cool Mode as desired.
3. To make adjustments to sengs, tap (menu), and then select
Advanced Sengs.
It is recommended that “Tankless” is set to On in most
applicaons for opmal performance.
4. Congure sengs as desired (or accept defaults), and then
tap (SAVE).
5. To check the model and mode, go to (menu) and select
About.