Controls - Continued
Cleaning
Troubleshooting
Owner’s Manual
Your new product is pre-programmed to run automatic settings when energized. During the
defrost cycle, a pre-set interval will commence internal components to melt any accumulated
frost on your evaporator, and the fan will continue to circulate air throughout your unit. Manual
defrost can be enabled by pressing both the “SNOWFLAKE” button and the “DOWN” button for
approximately 3 seconds.
The compressor is not running.
Check your circuit breaker.
Check if your power cord is unplugged.
Check if your thermostat is too high.
Check if your machine is in a defrost cycle.
The condensing unit is running for too long.
Check if an excessive amount of warm product has been placed inside the cabinet.
Check if the door has been left open for too long, or if the door is open.
Check if the door gasket is sealing properly.
Check if the condenser or evaporator coil is dirty.
Check if the evaporator coil is iced up.
The cabinet temperature is too warm.
Check if the thermostat is set too high.
Check if the airow is blocked.
Check if an excessive amount of warm product has been placed inside the cabinet.
When cleaning your cabinet or shelves, we recommend using warm water with a mild soap.
Your evaporator and condenser will require annual maintenance cleaning to be conducted by a
refrigeration technician.