D D
TAPE
READ
MAP
~
~
2 2
PAGE 23
OF
45
209
Defective tape switch assembly (refer
to
202).
Check/replace
the
tape internal cable (refer
to
202).
210
-Probe tape control card pin U 13 (+file protect).
Is
the
DOWN
light
on?
Y N
211
Defective tape control card (refer
to
202).
212
-Probe F2-P04 (+file protect).
Is
the
DOWN
light
on?
Y N
213
Check/replace the tape drive cable (refer
to
202).
214
Defective
F2
(base
I/O)
card.
B
D
7
MAP
0300-23
215
(Entry
Point
E)
ERROR
948--STATUS ERROR.
Cartridge in place status
not
active (status
bit
3
was
0, should have been
1).
-Remove the cartridge
from
the
tape drive.
-Determine
if
the problem is electrical or
mechanical
by
manually pressing the cartridge
in
place switch. The cartridge in place switch can
be seen by looking into the
front
of
the tape
drive,
it
is the rightmost
switch
(refer
to
202).
-While
manually pressing the cartridge in place
switch:
-Retry the test (press R on the keyboard).
Pressing R causes this section
of
the tape read
diagnotic program
to
run again.
Is ERROR
948
still
displayed?
Y N
216
The cartridge in place switch operates
electrically.
Service
check/adjust
the switch assembly
(refer
to
221).
Service
check/adjust
the cartridge stop blocks
(refer
to
224).
Defective tape switch assembly (refer
to
202).
Defective diagnostic tape cartridge.
217
The problem is
an
electrical problem not
I;In
adjustment problem.
-Replace the cartridge in the tape drive.
(refer
to
the appendix, the general logic probe).
-Probe tape control card B08 (gnd) (refer
to
227).
Is
the
DOWN
light
on?
Y N
2
4
D
S
218
Defective tape control card (refer
to
202).
28SEP76
PN
1608386
EC
829670
PEC
828851·
MAP
0300-23