Installing PeerMaster LAN Software
Using Novell NetWare Monitor
The Novell NetWare MONITOR.NLM provides custom statistics for
VNET.LAN and MXPCI4BT.LAN.
Custom Statistics for VNET.LAN You can display custom
statistics for VNET.LAN using MONITOR.NLM. You can select a
specific instance of VNET.LAN when multiple instances are loaded.
A specific instance of VNET.LAN can be uniquely identified when
multiple instances are loaded by two parameters: slot number and
frame type. The following example shows how MONITOR.NLM
prompts you to select among three instances of VNET.LAN.
VNET SLOT=41 FRAME=ETHERNET_82.2
VNET SLOT=C FRAME=ETHERNET_82.3
VNET SLOT=C FRAME=ETHERNET_82.2
Note: Slot numbers do not correspond to either physical or pseudo
slot numbers. This is because a single instance of VNET.LAN
might include multiple physical PeerMaster adapters. For
this reason, VNET.LAN slot numbers are represented as bit
masks. To ensure that VNET.LAN slot numbers do not
conflict with physical slot numbers, the least significant eight
bits of the mask are always set to 0. The upper eight bits of
the mask–bits 8 through 15–represent the physical slots 1
through 8. The following table shows the relationship
between VNET.LAN slot numbers and physical slot numbers.
The VNET slot number of 4100 specifies an instance of VNET.LAN
that includes the PeerMaster adapters configured to slots 7 and 1.
The sample slot value of 0C00 specifies a VNET.LAN including the
PeerMaster adapters configured to slots 3 and 4. Note that multiple
instances of VNET.LAN include the PeerMaster adapters configured
VNET.LAN Slot Slot Number
100 1
200 2
400 3
800 4
1000 5
2000 6
4000 7
8000 8