Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0512 Timeout, no action detected. Reinitialize the operation
No action was detected for the installation or removal of disk unit K11, and
the bus was released.
You must reinitialize the operation to continue.
0513 Timeout, no action detected. Reinitialize the operation
No action was detected for the installation or removal of disk unit K12,
and the bus was released.
You must reinitialize the operation to continue.
0514 Timeout, no action detected. Reinitialize the operation
No action was detected for the installation or removal of disk unit K13,
and the bus was released.
You must reinitialize the operation to continue.
0515 Timeout, no action detected. Reinitialize the operation
No action was detected for the installation or removal of disk unit K14,
and the bus was released.
You must reinitialize the operation to continue.
0516 Timeout, no action detected. Reinitialize the operation
No action was detected for the installation or removal of device 1, and the
bus was released.
You must reinitialize the operation to continue.
0517 Timeout, no action detected. Reinitialize the operation
No action was detected for the installation or removal of device 2, and the
bus was released.
You must reinitialize the operation to continue.
0518 Timeout, no action detected. Reinitialize the operation.
No action was detected for the installation or removal of disk unit 9, and
the bus was released.
You must reinitialize the operation to continue.
0519 Timeout, no action detected. Reinitialize the operation.
No action was detected for the installation or removal of disk unit 10, and
the bus was released.
You must reinitialize the operation to continue.
051A Timeout, no action detected. Reinitialize the operation.
No action was detected for the installation or removal of disk unit 11, and
the bus was released.
You must reinitialize the operation to continue.
1xxx
System Reference Codes 81

Table of Contents

Other manuals for IBM iSeries 270

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 270 and is the answer not in the manual?

IBM iSeries 270 Specifications

General IconGeneral
BrandIBM
ModeliSeries 270
CategoryServer
LanguageEnglish

Related product manuals