v No: Continue with the next step.
v Yes: The backplane card may be the failing item. See symbolic FRU “BACKPLN” on page 284 to
exchange the failing item. See Locations and addresses. If the error did not go away, exchange the
cable between the panel and the card, part 44H8022 or 44H8017. See Locations and addresses.
This
ends the procedure.
7. Is the SRC 1xxx 2222, 2223, 2322 or 2323?
v No: Continue with the next step.
v Yes: See symbolic FRU (“TWRCARD” on page 470) only for these SRCs.
8. Is the SRC 1xxx 2224 or 2324?
v Yes: Continue with the next step.
v No: Go to “Starting point for all problems” on page 2.
This ends the procedure.
9. Are you working on a unit with a SPD card enclosure with the 2735 card installed correctly?
v No: Exchange the following parts one at a time:
PCI I/O card - part 45H1235 (see Locations and addresses).
The cable between the SP/PCI I/O card and the PCI I/O card - part 44H8038. See Locations
and addresses.
The SP/PCI/ I/O card - part 45H1226. See Locations and Addresses.
This
ends the procedure.
v
Yes: Exchange the following parts one at a time:
2735 optical Bus IOP - part 44H7791
SPD backplane - part 44H7994
This
ends the procedure.
10. Is the AC line cord from the FC 7104 power supply to the customer’s AC power outlet connected and
seated correctly at both ends?
v Yes: Continue with the next step.
v No: Connect the AC line cord correctly at both ends.
This
ends the procedure.
11.
Perform the following:
a. Disconnect the FC 7104 AC line cord from the customer’s AC outlet.
b. Use a multimeter to measure the AC voltage at the customer’s AC outlet.
Is
the AC voltage 100V to 127V or 200V to 240V?
v Yes: Continue with the next step.
v No: Inform the customer that the AC voltage at the power outlet is not correct. Reconnect the line
cord after the voltage has been corrected.
This
ends the procedure.
12. Perform the following:
a. Reconnect the AC line cord to the AC outlet.
b. Disconnect the AC line cord from the FC 7104.
c. Use a multimeter to measure the AC voltage at the end of the line cord.
Is
the voltage 100V to 127V or 200V to 240V?
v Yes: Reconnect the line cord to the FC 7104 and perform “Power PIP9” on page 172 on the FC
7104 system unit expansion.
This
ends the procedure.
v No: Exchange the failing AC line cord.
This ends the procedure.
Instructions for Models 800, 810, 825, 870, and 890
410 iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation

Table of Contents

Other manuals for IBM iSeries 270

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 270 and is the answer not in the manual?

IBM iSeries 270 Specifications

General IconGeneral
BrandIBM
ModeliSeries 270
CategoryServer
LanguageEnglish

Related product manuals