Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
6118 Regulator over current fault
One of the regulators detected an over current condition. This may be
caused by the regulator or one of cards powered by the regulator.
PWRREG
BKSPCN
6218 Regulator over current fault
Regulator 1 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
PWRREG
BKSPCN
6238 Regulator over current fault
Regulator 2 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
PWRREG
BKSPCN
6258 Regulator over current fault
Regulator 3 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
PWRREG
ACMODUL
6318 Regulator Fault
Regulator 1 has reported a fault.
PWRREG
BKSPCN
631A Regulator Fault
Regulator 1 has reported a fault.
PWRREG
ACMODUL
FI00030
6338 Regulator Fault
Regulator 2 reported a fault.
PWRREG
BKSPCN
633A Regulator Fault
Regulator 2 reported a fault.
PWRREG
ACMODUL
FI00030
6358 Regulator Fault
A regulator 3 reported a fault.
PWRREG
ACMODUL
6400 to 6401 Power Good Fault PGDPART
FI00065
BKSPCN
6518 One of the regulators has reported a fault
An over current sensor failure occurred for a regulator. The ac module or
one of the regulators can cause this fault.
PWRREG
BKSPCN
6618 Regulator over current fault
Regulator 1 reported a false over current condition.
Fault tolerance may allow continued system operation.
PWRREG
BKSPCN
6638 Regulator over current fault
Regulator 2 reported a false over current condition.
Fault tolerance may allow continued system operation.
PWRREG
BKSPCN
6658 Regulator over current fault
Regulator 3 reported a false over current condition.
Fault tolerance may allow continued system operation.
PWRREG
ACMODUL
1xxx
98
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals