Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0224 Device detected wrong start command from WS IOP FI00604
AJLYD01
FI00610
0225 WS IOP detected wrong exception response from device FI00604
FI00610
0226, 0230 to 0239,
0240 to 0248
Printer detected equipment error FI00604
0249 WS IOP detected wrong request or response from device FI00604
FI00610
026X, 027X, 028X Printer detected equipment error
See printer documentation for more information.
FI00604
0290 WS IOP detected no status change from device FI00604
FI00610
0291 WS IOP detected busy time-out from device FI00604
FI00610
02A0 to 02AF,
02FF
Printer detected equipment error
Consult the printers manual for additional information.
FI00604
A000 Too many devices active on the workstation IOP
This error occurs if you attempted to activate more workstations than
allowed.
Switch off power to (or remove) one or more of the display stations (except
for the console) that are attached to this workstation I/O processor.
Perform an initial program load (IPL) from the control panel to correct the
problem.
Refer to the local workstation diagrams for the location of workstations if
necessary.
GAUBBBB
B000 WS IOP fails to report part, model and serial number
Perform TWSC-PIP1.
FI00610
C000 WS IOP error not known AJLYD01
FI00610
D000 Work Station IOA start-up test error FI00610
D010 WS IOP storage failure corrected
Perform TWSC-PIP1.
FI00610
D011 WS IOP card storage failure FI00610
D021 WS IOP detected errors on all cables FI00602
FI00601
FI00610
FI00615
D022 WS IOP parity errors detected on all cables FI00602
FI00601
FI00610
FI00615
D023 WS IOP detected errors on some, but not all cables
Perform TWSC-PIP1.
FI00602
FI00601
FI00610
B070
System Reference Codes 219

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals