Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9012 Address not valid.
LIC command had a frame address that was not valid.
Exchange the SPCN frame-to-frame cables to the failing frame.
TWRCARD
CBLALL
9013 Invalid Node Address.
The address in the SPCN command does not match the secondary nodes
assigned address.
Exchange the failing items for the SPCN node reporting the error.
TWRCARD
CBLALL
9014 A command has an invalid address mode.
A command from the system unit specified a unit address of D or E or had
a frame address of 00.
Exchange the failing items in the system unit.
AJDG301
TWRCARD
9016, 9021 A command to an SPCN node was rejected.
No action required. This reference code is logged for information only.
9022 Addressed Unit not in frame.
The addressed unit does not exist in the addressed frame.
No action required. This reference code is logged for information only.
9023 Addressed Unit exists, but the frame is powered off.
The addressed unit is in a frame that is powered off.
No action required. This reference code is logged for information only.
9024 SPCN Licensed Internal Code not valid.
The Licensed Internal Code in one of the secondary nodes is not valid. The
code will be reloaded.
No action required. This reference code is logged for error analysis only.
9025 SPCN Licensed Internal Code is not valid.
The Licensed Internal Code in one of the frames is not valid. The code will
be reloaded.
No action required. This reference code is logged for error analysis only.
9026 Battery Power Unit is reporting a low charge.
The battery power unit is not charged enough to run a test.
No action required. This reference code is logged for information only.
9027 Battery Power Unit is defective.
No action required. This reference code is logged for information only.
9028 SPCN Licensed Internal Code is not valid.
The Licensed Internal Code in the primary node is not valid. The code will
be reloaded.
No action required. This reference code is logged for error analysis only.
1xxx
System Reference Codes 47

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals