Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9029 SPCN VPD Damaged
The VPD record in the EEPROM has bad data.
Exchange the failing items for the node reporting the failure.
TWRCARD
902C Battery Power Unit test was aborted.
The battery power unit test was aborted.
No action required. This reference code is logged for information only.
902D Addressed frame is not in SPCN configuration table.
The addressed frame is not in the SPCN configuration table.
No action required. This reference code is logged for information only.
9031 Frame-to-Frame Communications Failure
The SPCN detected a BCC error on a transmission from another frame. The
transmission is attempted again.
No action required. This reference code is logged for error analysis only.
9032 SPCN Communications Failure, unit to rack.
The frame detected a BCC error on a transmission from a secondary node
to the frame. The transmission is attempted again.
No action required. This reference code is logged for error analysis only.
9033 SPCN Communications Failure, rack to unit.
A secondary node detected a BCC error on a transmission from the frame.
The transmission is attempted again.
No action required. This reference code is logged for error analysis only.
9034 Unsupported Packet Size
The receiving node detected a packet exceeding 70 bytes. The frame can
also return this code if a secondary node returns more than 10 bytes to a
PAS command.
No action required. This reference code is logged for error analysis only.
9035 Secondary SPCN node timeout.
A secondary SPCN node did not respond to a command. The command
was attempted again and failed.
No action required. This reference code is logged for error analysis only.
9036 Frame Timeout
One or more frames did not respond to a command. The command is
attempted again.
No action required. This reference code is logged for error analysis only.
903B Invalid Packet Length for data sent.
The number of bytes sent or received does not match the number of bytes
specified in the command.
No action required. This reference code is logged for error analysis only.
1xxx
48
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals