Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9212 Frame Address field not valid.
A Licensed Internal Code command had a frame address that is not valid.
Exchange the failing items for the failing node.
TWRCARD
9213 Invalid Address status, secondary node.
The address in the SPCN command does not match the assigned address of
the secondary node.
Exchange the failing items for the failing node.
TWRCARD
9214 Invalid Address Mode status
Invalid Address Mode occurred during Frame Command processing.
TWRCARD
AJDG301
9215 Invalid Frame Command status
Invalid Frame Command occurred during Frame Command processing.
TWRCARD
AJDG301
921B System Unit SPCN Port Fault status.
System Unit Port Fault occurred during Command processing.
TWRCARD
AJDG301
922B Address Unassigned status
A secondary node has no address assigned during Command processing.
TWRCARD
AJDG301
9231 Frame-to-Frame Communications Failure
A frame-to-frame communications failure occurred during STF processing.
TWRCARD
CBLALL
9232 Intrarack Communications Failure
An SPCN secondary node to frame communications failure occurred
during Command processing.
TWRCARD
CBLALL
9233 Intrarack Communications Failure
An SPCN frame to secondary node communications failure occurred
during Command processing.
TWRCARD
CBLALL
9234 Unsupported Packet Size status
Unsupported Packet Size occurred during STF and Secondary Node
Command processing.
TWRCARD
CTLPNL
SVCPROC
9235 SPCN Secondary Node Timeout status
An SPCN Secondary Node Timeout occurred during Command processing.
If the failing secondary node is in a 9337, go to the Analyzing Problems
section in the 9337 Disk Array Service Information manual.
TWRCARD
AJDG301
CBLALL
9236 Frame Timeout status
An SPCN Frame Node Timeout occurred during Network post processing.
TWRCARD
CBLALL
9238 Secondary Node Fault
An SPCN Secondary Node Fault occurred during Command processing.
TWRCARD
AJDG301
9239 Frame Node Fault
An internal error in the SPCN frame node prevents the running of a Frame
command.
TWRCARD
AJDG301
1xxx
System Reference Codes 51

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals