Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9104 Download Completion Timeout
An SPCN node failed to leave the download state.
Exchange the failing SPCN node.
TWRCARD
9105 Load Damaged Timeout
An SPCN node failed to enter the operational state.
Exchange the failing SPCN node.
TWRCARD
9106 An SPCN LID was not found.
No action required. This reference code is logged for information only.
9107 An SPCN microcode download is required.
No action required. This reference code is logged for error analysis only.
9108 A status change occured in one of the SPCN nodes.
No action required. This reference code is logged for information only.
9109 Licensed Internal Code part number is not correct.
The AROS part number field was not updated to the correct level after the
system attempted to load new Licensed Internal Code.
TWRCARD
9110 Battery Power Unit capacity test failed.
The battery power unit was not able to pass the capacity test.
BATRY
9111 SPCN is too large for VLIC.
There are more nodes in the network than VLIC can service.
AJDG301
9112 Primary SPCN node is reporting load damaged.
The Licensed Internal Code for the primary SPCN node is damaged. The
reload failed because the code could not be found.
TWRCARD
9113 Secondary SPCN node is reporting load damaged.
The Licensed Internal Code for the secondary SPCN node is damaged. The
reload failed because the code could not be found.
TWRCARD
9114 Frame SPCN node is reporting load damaged.
The Licensed Internal Code for a SPCN node is damaged. The reload failed
because the code could not be found.
TWRCARD
9115 SPCN Command rejected by the Service Processor.
The service processor rejected an SPCN command from the Licensed
Internal Code.
No action required. This reference code is logged for information only.
9116 SPCN - Control Panel interface failure.
The SPCN to control panel interface is not working.
9117 SPCN - Control Panel interface is now working.
The SPCN to control panel interface is now working.
No action required. This reference code is logged for information only.
1xxx
50
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals