Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
2131 Power Supply P01 Fault
A fault has been detected for Power Supply P01.
PWRSPLY
SPNLCRD
2132 Power Supply P02 Fault
A fault has been detected for Power Supply P02.
PWRSPLY
SPNLCRD
2133 Power Supply P03 Fault
A fault has been detected for Power Supply P03.
PWRSPLY
SPNLCRD
2134 Power Supply P04 Fault
A fault has been detected for Power Supply P04.
PWRSPLY
SPNLCRD
2141 Power Supply P01 Fault
A fault has been detected for Power Supply P01.
PWRSPLY
SPNLCRD
2142 Power Supply P02 Fault
A fault has been detected for Power Supply P02.
PWRSPLY
SPNLCRD
2143 Power Supply P03 Fault
A fault has been detected for Power Supply P03.
PWRSPLY
SPNLCRD
2144 Power Supply P04 Fault
A fault has been detected for Power Supply P04.
PWRSPLY
SPNLCRD
2151 Power Supply P01 Fault
A fault has been detected for Power Supply P01.
PWRSPLY
SPNLCRD
2152 Power Supply P02 Fault
A fault has been detected for Power Supply P02.
PWRSPLY
SPNLCRD
2153 Power Supply P03 Fault
A fault has been detected for Power Supply P03.
PWRSPLY
SPNLCRD
2154 Power Supply P04 Fault
A fault has been detected for Power Supply P04.
PWRSPLY
SPNLCRD
2201 Power Supply P01 or P02 Overcurrent Fault
A POW-PIP is required for identifying which load is at fault.
PWROC
SPNLCRD
CBLALL
2202 Power Supply P03 or P04 Overcurrent Fault
A POW-PIP is required for identifying which load is at fault.
PWROC
SPNLCRD
CBLALL
2210 One of the CPM regulators has reported a fault PWRSPLY
SPNLCRD
2211 CPM Regulator 1 Fault PWRSPLY
SPNLCRD
2212 CPM Regulator 2 Fault PWRSPLY
SPNLCRD
2213 CPM Regulator 3 Fault PWRSPLY
SPNLCRD
2221 Power Good Fault
A MFIOP power good fault occurred.
SPNLCRD
PGDPART
CBLALL
1xxx
System Reference Codes 93