Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
2222 Power Good Type M Fault
A Memory power good fault occurred.
SPNLCRD
PGDPART
CBLALL
2223 Power Good Type P Fault
A Processor power good fault occurred.
SPNLCRD
PGDPART
CBLALL
2224 Power Good Type I Fault
A Internal expansion power good fault occurred.
SPNLCRD
PGDPART
CBLALL
2231 System Unit Interlock Failure INTRLCK
SPNLCRD
CBLALL
2232 Secondary Frame Interlock Failure INTRLCK
SPNLCRD
CBLALL
2240 Air Moving Device Panel Fault AIRMOVR
PWRSPLY
2241 Air Moving Device 1 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
AIRMOVR
SPNLCRD
2242 Air Moving Device 2 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
AIRMOVR
SPNLCRD
2244 Air Moving Device 4 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
AIRMOVR
SPNLCRD
2245 Air Moving Device 5 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
AIRMOVR
SPNLCRD
2246 Air Moving Device 6 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
AIRMOVR
SPNLCRD
2260 Timeout on Panel for Request of VPD CTLPNL
2301 Power Supply P01 or P02 Overcurrent error
A POW-PIP is required for identifying which load is at fault.
PWROC
SPNLCRD
CBLALL
2302 Power Supply P03 or P04 Overcurrent error
A POW-PIP is required for identifying which load is at fault.
PWROC
SPNLCRD
CBLALL
2311 Power Supply P01 error
A fault detection failure occurred for Power Supply P01.
PWRSPLY
SPNLCRD
CBLALL
1xxx
94
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals