Failing item code Description/Action
FI00251 FI00251 indicates that a battery power unit is the failing item.
The following list shows the possible failing items:
v System units, extension units, storage expansion units, and the base I/O tower (9251) use
the following:
– For 9910 type uninterruptible power supply call IBM
(R)
Service Support. For all other
uninterruptible power supply units, call the uninterruptible power supply provider.
– Internal battery unit pack assembly (see Locations for the model you are working on
for part number information and remove and replace procedures)
– Battery power unit charger — part 21H7060
– External battery unit (see Type, model, and part number list for part number
information)
– External battery unit cable — part 21H7695
v
Expansion battery power unit 1 and 2 battery pack — part 87G8048
v Internal battery power unit 1 and 2 charger (see Type, model, and part number list for
part number information)
v 9309 general purpose I/O frame with SPCN (FC 9171) — part 21F9380
FI00253 This failing item is in a migrated tower. See the failing item table for this failing item in the
Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the V5R1
Supplemental Manuals web site
.
FI00255 This failing item is in a migrated tower. See the failing item table for this failing item in the
Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the V5R1
Supplemental Manuals web site
.
FI00256 This failing item is in a migrated tower. See the failing item table for this failing item in the
Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the V5R1
Supplemental Manuals web site
.
FI00300 FI00300 indicates that media is the failing item.
If the load source is:
v Tape, exchange the tape in the alternate IPL tape unit.
v An optical storage unit, exchange the compact disk.
v DASD, exchange the DASD.
If
installing from:
v Tape, exchange the tape in the alternate IPL tape unit.
v An optical storage unit, exchange the compact disk.
FI00301 FI00301 indicates that the magnetic storage I/O processor (MSIOP) or the combined
function I/O processor (CFIOP) is the failing item.
Use the IOP type to determine the part.
FI00302 FI00302 indicates that the Licensed Internal Code for the magnetic storage I/O processor
(MSIOP) or the combined function I/O processor (CFIOP) is the failing item.
Ask your next level of support for assistance.
FI00310 FI00310 indicates that an I/O processor card or an I/O adapter card is the failing item.
Perform Bus PIP1 in the Migrated Expansion Tower Problem Analysis, Repair and Parts
manual on the V5R1 Supplemental Manuals web site
.
FI00315 FI00315 indicates that the battery power unit install time life has been exceeded.
256 iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and