Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
9350 Tape unit detected a read or write error on tape medium
A permanent read or write error occured. Clean the tape unit and retry the
operation.
If cleaning the tape unit does not correct the problem, exchange the tape
media.
ML2TMED
46G2227
46G3934
42F7300
9351 Tape with excessive error rate was mounted in tape device.
The tape unit detected that the mounted tape cartridge has a history of
excessive read and write errors. It is recommended that you exchange the
tape cartridge.
ML2TMED
UL2CLN
46G2227
9355 The data format is incorrect; the tape cannot be read
The tape unit has detected that the data format on the tape media is not
supported.
Clean the tape unit and retry the operation.
If the operation continues to fail, use a different tape cartridge.
UL2USR1
ML2TMED
UL2CLN
46G2227
9500 I/O processor Licensed Internal Code error
If the system is operational, take a dump of the I/O processor data. For
more information, see the iSeries Service Functions information or ask your
next level of support for assistance.
FI00130
9800 to 9803 I/O processor successfully recovered from temporary error
No action required. This reference code is logged for information only.
9810 Problem analysis has determined a part should be replaced.
This reference code is used for ending Online Problem Analysis with a list
of failing items. (Information only)
9899 Problem analysis completed, the problem has been corrected.
This reference code is used for ending Online Problem Analysis when no
problem was found or the problem was corrected.
UL2FIXD
9900, FF09 Licensed Internal Code for tape unit was not upgraded
The I/O processor loading of Licensed Internal Code (LIC) to the
programmable tape drive was not completed.
The tape drive will continue to operate with the previous LIC. You may do
either of the following:
v Wait for next IPL when the system will attempt to load the LIC for the
tape drive again.
v Perform TU-PIP4 to reset the IOP and the tape drive. When the IOP is
reset, if the device has the wrong level of LIC, the IOP will attempt to
load the new LIC.
UL2WAIT
FF4D I/O processor successfully recovered from temporary error
No action required. This reference code is logged for information only.
When the system is available, display the operator messages, find message
CPI946B, and press F14 to run online problem analysis to see if the error
threshhold has been exceeded.
46G2227
FI00141
FI00830
46G2599
46G3934
17G1500
42F7300
AJEDA00
7208
190
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)

Table of Contents

Other manuals for IBM iSeries Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries Series and is the answer not in the manual?

IBM iSeries Series Specifications

General IconGeneral
BrandIBM
ModeliSeries Series
CategoryServer
LanguageEnglish

Related product manuals