EasyManua.ls Logo

IBM x3550 - System - 7978 User Manual

IBM x3550 - System - 7978
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Welcome.
Thank you for buying an
IBM server.
This server
contains information for setting
up and configuring your server.
For detailed information about
your server, view the publications
on the
You can also find the most
current information about
your server at http://www.ibm.com/
systems/support/.
Your server
is based on the X-Architecture
technology, and it features
superior performance, availability,
and affordability.
Documentation CD.
Installation Guide
Installation Guide
System x3550
Type 7978
Turn off the server
and install options.
Did the server
start correctly?
Ye s
No
Go to the Server Support
flow chart on the reverse
side of this page.
Start the server.
Did the server
start correctly?
Ye s
No
Install the server in the rack cabinet
and cable the server and options;
then, restart the server.
Was the
server setup
completed?
Use
ServerGuide to
install the operating
system?
The server is ready to use.
Go to
to register the server.
http://www.ibm.com/support/mysupport/
Go to the Web for instructions:
http://www.ibm.com/systems/
support/
No
Ye s
Ye s
No
Use the IBM
ServerGuide program
to set up and
configure hardware.
Go to the Server Support
flow chart on the reverse
side of this page.
Install applications,
such as IBM systems
management software
and IBM ServeRAID
programs

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the IBM x3550 - System - 7978 and is the answer not in the manual?

IBM x3550 - System - 7978 Specifications

General IconGeneral
ProcessorIntel Xeon
Processor SpeedUp to 3.0 GHz
Number of Processors1 or 2
ChipsetIntel 5000P
MemoryUp to 32 GB DDR2
StorageSAS or SATA
Drive BaysUp to 6
Network InterfaceDual Gigabit Ethernet
Power Supply670W or 835W redundant power supplies
Operating System SupportWindows Server, Linux, VMware

Summary

Chapter 1. Introduction

The IBM System x Documentation CD

Contains documentation in PDF format and includes a browser tool for quick information access.

Hardware and software requirements

Lists the minimum hardware and software needed to use the IBM System x Documentation CD.

Using the Documentation Browser

Instructions on how to browse, read, and view documents using the provided browser.

Features and specifications

Provides a summary of the server's key features and technical specifications.

Notices and statements in this document

Explains the meaning and usage of caution and danger statements within the document.

Major components of the server

Illustrates and labels the main physical components of the IBM System x3550 server.

Chapter 2. Installing options

Installation guidelines

Provides safety and general advice before proceeding with installing server options.

System reliability guidelines

Outlines requirements to ensure proper system cooling and overall reliability.

Working inside the server with the power on

Details precautions for safely performing tasks inside a powered-on server.

Handling static-sensitive devices

Provides instructions to prevent damage to components from electrostatic discharge.

Removing the server cover

Step-by-step instructions for safely removing the server's outer cover.

Removing air baffles

Instructions for removing internal air baffles to access components.

Installing a hard disk drive

Guide for installing hard disk drives, including types supported and configurations.

Installing a hot-swap hard disk drive

Detailed steps for installing SAS or SATA hot-swap hard disk drives.

Installing a simple-swap hard disk drive

Detailed steps for installing simple-swap SATA hard disk drives.

Replacing a riser-card assembly

Instructions for replacing PCI Express riser-card assemblies.

Installing an adapter

Steps for installing various adapter cards into the server's PCI slots.

Replacing the RAID SAS controller

Procedure for replacing the ServeRAID SAS controller in supported models.

Installing a memory module

Guide for installing DIMM memory modules, including compatibility and sequence.

Installing a microprocessor

Detailed steps for installing a microprocessor into the server's socket.

Installing a Remote Supervisor Adapter II SlimLine

Steps for installing the optional Remote Supervisor Adapter II SlimLine.

Completing the installation

Final steps required after installing hardware options and closing the server.

Replacing the server cover

Instructions for reinstalling the server cover after component installation.

Connecting the cables

Illustrations and descriptions of server front and rear connectors for cabling.

Updating the server configuration

Process for saving new hardware configuration settings after changes.

Chapter 3. Server controls, LEDs, connectors, and power

Front view

Identifies controls, LEDs, and connectors located on the server's front panel.

Rear view

Identifies connectors and LEDs located on the server's rear panel.

Server power features

Details how the server operates when connected to an AC power source.

Turning on the server

Describes the methods and steps to power on the server.

Turning off the server

Describes the methods and steps to power off the server.

Chapter 4. Configuring the server

Using the ServerGuide Setup and Installation CD

Guide for using the ServerGuide CD to detect hardware and simplify OS installation.

Configuring hot-swap SAS or hot-swap SATA RAID

Instructions for configuring redundant arrays of independent disks (RAID).

Using the IBM ServeRAID Configuration Utility program

Details on using the ServeRAID utility for array configuration and management.

Using ServeRAID Manager

Instructions for using ServeRAID Manager for RAID controller configuration.

Configuring simple-swap SATA RAID

Steps to configure simple-swap SATA RAID using the Adaptec utility.

Using the Adaptec RAID Configuration Utility program

Utility to add RAID level-0 and level-1 functionality to integrated SATA controllers.

Using the SATA HostRAID feature

Instructions for performing an initial RAID level-1 configuration.

Using the baseboard management controller utility program

Overview of BMC utility for basic service-processor monitoring and remote management.

Enabling and configuring SOL using the OSA SMBridge management utility program

Steps to enable and configure Serial over LAN (SOL) for remote server management.

BIOS update and configuration

Procedures for updating and configuring BIOS for SOL connection.

Chapter 5. Solving problems

Diagnostic tools overview

Lists the available tools for diagnosing and solving hardware-related problems.

POST beep codes

Explains POST beep codes which indicate detection of startup problems.

POST error codes

Lists abbreviated POST error codes and the recommended actions to resolve them.

ServerGuide problems

Troubleshooting guidance for common issues encountered with ServerGuide.

Troubleshooting tables

Tables that list problem symptoms and suggest corrective actions.

CD-RW/DVD drive problems

Troubleshooting steps for issues related to the CD-RW/DVD drive.

General problems

General troubleshooting steps for common server issues.

Hard disk drive problems

Troubleshooting steps for issues related to hard disk drives.

Intermittent problems

Guidance for troubleshooting problems that occur occasionally and are difficult to diagnose.

USB keyboard, mouse, or pointing-device problems

Troubleshooting steps for issues with USB keyboards, mice, and pointing devices.

Memory problems

Troubleshooting steps for issues related to system memory modules (DIMMs).

Microprocessor problems

Troubleshooting steps for issues related to the server's microprocessor.

Monitor problems

Troubleshooting steps for display and monitor-related issues.

Optional-device problems

Troubleshooting steps for issues with installed optional devices.

Power problems

Troubleshooting steps for issues related to the server's power supply.

Serial port problems

Troubleshooting steps for issues related to serial ports and devices.

Software problems

Troubleshooting steps for issues related to server software.

Universal Serial Bus (USB) port problems

Troubleshooting steps for issues related to USB ports.

Video problems

Troubleshooting steps for video output and display issues.

Light path diagnostics

Explains how to use light path diagnostics for error identification.

Diagnosing problems using light path diagnostics

Steps for diagnosing errors by viewing light path LEDs.

Light path diagnostics LEDs

Lists LEDs on the light path panel, their meanings, and troubleshooting actions.

Appendix A. Getting help and technical assistance

Before you call

Steps to perform before contacting IBM support to solve problems.

Using the documentation

Guidance on accessing and using the provided documentation and online help.

Getting help and information from the World Wide Web

Resources for technical information and support available on the IBM website.

Software service and support

Information on obtaining IBM support for software-related issues.

Hardware service and support

Information on obtaining IBM support for hardware-related issues.

IBM Taiwan product service

Contact information for IBM product service and support in Taiwan.

Appendix B. Notices

Trademarks

Lists trademarks of International Business Machines Corporation.

Important notes

Clarifies definitions for processor speed, drive speeds, and storage capacity units.

Product recycling and disposal

Guidelines for responsible recycling and disposal of IT equipment.

Battery return program

Information on battery recycling, disposal, and return programs.

Electronic emission notices

Statements regarding FCC, IC, EMC, and other electronic emission regulations.

Related product manuals