v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide on the IBM System x Documentation
CD to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A hard disk drive that you are
installing does not fit correctly in
the cage.
Make sure that the type of drive is correct for this server.
Intermittent problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide on the IBM System x Documentation
CD to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
A problem occurs only
occasionally and is difficult to
diagnose.
1. Make sure that:
v All cables and cords are connected securely to the rear of the server and
attached devices.
v There is adequate cooling airflow. Reduced airflow due to a failed fan or an
internal or external obstruction can cause the server to overheat and shut
down.
2.
Check the system-error log or the BMC log (see “Error Logs” in the Problem
Determination and Service Guide).
If
the problem remains, call for service.
The server resets (restarts)
occasionally
1. If the reset occurs during POST and the POST watchdog timer is enabled (click
Advanced Setup --> Baseboard Management Controller (BMC) Setting -->
BMC Post Watchdog in the Configuration/Setup Utility program to see the
POST watchdog setting), make sure that sufficient time is allowed in the
watchdog timeout value (BMC POST Watchdog Timeout). See the User’s
Guide for information about the settings in the Configuration/Setup Utility
program. If the server continues to reset during POST, see the “POST” and
“Diagnostic programs” sections in the Problem Determination and Service
Guide.
2. If the reset occurs after the operating system starts, disable any automatic
server restart (ASR) utilities, such as the IBM Automatic Server Restart IPMI
Application for Windows, or ASR devices that may be installed.
Note: ASR utilities operate as operating-system utilities and are related to the
IPMI device driver. If the reset continues to occur after the operating system
starts, the operating system might have a problem; see “Software problems” on
page 68.
3. If neither condition applies, check the system-error log or BMC log (see “Error
Logs” in the Problem Determination and Service Guide).
If
the problem remains, call for service.
58 IBM System x3550 Type 7978: Installation Guide