Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
0022 Device detected storage or data overrun
Perform TWSC-PIP1.
FI00601
AJLYD01
FI00610
0023 Device detected null or attribute exception error
Perform TWSC-PIP1.
FI00601
FI00610
0024 Device detected wrong start command from WS IOP
Perform TWSC-PIP1.
FI00601
AJLYD01
FI00610
0025 WS IOP detected wrong exception response from device
Perform TWSC-PIP1.
FI00601
FI00610
0026 WS IOP detected not valid pass-through command
Perform TWSC-PIP1.
GAU9999
FI00610
0049 WS IOP detected wrong request or response from device
Perform TWSC-PIP1.
FI00601
FI00610
0082 WS IOP detected wrong device type from device
Perform TWSC-PIP1.
FI00601
0090 WS IOP detected no status change from device
Perform TWSC-PIP1.
FI00601
FI00610
0091 WS IOP detected busy time-out from device
Perform TWSC-PIP1.
FI00601
FI00610
0100 Device no response time-out; temporary error FI00601
FI00602
FI00610
0101 WS IOP detected error when transmitting data
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00602
FI00601
GAU7777
GAU8888
FI00610
FI00615
0103 WS IOP detected parity error from device
Is the problem intermittent?
No Yes
↓ Perform the following procedures:
1. INT-PIP5
2. INT-PIP14
Perform TWSC-PIP1.
FI00602
FI00601
GAU7777
FI00610
B070
214
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)