Chapter 7. Nortel Networks L2/3 GbESM configuration and network integration 113
/cfg/l2/vlan 46/def ext5 ext6
/* for GbESM 2
/* /cfg/l2/vlan 35/def ext5 ext6
/* /cfg/l2/vlan 46/def ext1 ext2
/* both GbESMs use the below...
/cfg/l2/vlan 10/add ext3
/cfg/l2/vlan 20/add ext3
/* create L3 interfaces on VLANs
/* these are for the subnets where the servers are
/cfg/l3/if 10
ena
vlan 10
addr 10.10.0.243
/* addr 10.10.0.244 on GbESM 2
mask 255.255.255.0
/cfg/l3/if 20
ena
vlan 20
addr 10.20.0.243
/* addr 10.20.0.244 for GbESM 2
mask 255.255.255.0
/* these are for the uplink subnets
/cfg/l3/if 35
ena
vlan 35
addr 10.35.0.243 --
/* addr 10.35.0.244 for GbESM 2
mask 255.255.255.0
/cfg/l3/if 46
ena
vlan 46
addr 10.46.0.243
/* addr 10.46.0.244 for GbESM 2
mask 255.255.255.0
/* clean up VLAN 1 - remove unused ports
/c/l2/vlan 1
rem EXT1
rem EXT2
rem EXT3
rem EXT5
rem EXT6
/* clean up VLAN 5 - unused in this configuration
/c/l2/vlan 5
del