138 Nortel Networks L2/3 Ethernet Switch Module for IBM Eserver BladeCenter
/* above also INT3 on GbESM 2
/c/l2/vlan 35
/* use vlan 45 on GbESM 2
ena
name "VLAN 35"
def EXT1 EXT2
/c/l2/vlan 36
/* use vlan 46 on GbESM 2
ena
name "VLAN 36"
def EXT5 EXT6
/c/l2/stg 1/off
/c/l2/stg 1/clear
/c/l2/stg 1/add 1 10 20 35 36 50
/c/l2/trunk 1
ena
add EXT1
add EXT2
/c/l2/trunk 2
ena
add EXT5
add EXT6
/c/l3/if 10
ena
addr 10.10.0.243
/* -- 10.10.0.244 on GbESM 2
mask 255.255.255.0
broad 10.10.0.255
vlan 10
/c/l3/if 20
ena
addr 10.20.0.243
/* -- 10.20.0.244 on GbESM 2
mask 255.255.255.0
broad 10.20.0.255
vlan 20
/c/l3/if 35
/* -- this section uses if 45, vlan 45, address .244 on GbESM 2
ena
addr 10.35.0.243
mask 255.255.255.0
broad 10.35.0.255
vlan 35
/c/l3/if 36
/* -- this section uses if 46, vlan 46, address .244 on GbESM 2
ena
addr 10.36.0.243
mask 255.255.255.0
broad 10.36.0.255
vlan 36
/c/l3/vrrp/on
/c/l3/vrrp/vr 1
ena
vrid 1
if 10
prio 101
/* -- above only on GbESM 1, defaults to 100 on GbESM 2
addr 10.10.0.100