Circuit Breaker Panel
CAUTION:
Energy hazard, remove power before servicing.
Circuit Breaker Panel Removal
Attention: This unit may contain two circuit breaker panels. Both circuit breaker
panels will need to be disconnected from the customer's power source in
order to safely remove or service either circuit breaker panel.
Note: It is the customer's responsibility to have a qualified technician properly
disconnect the circuit breaker panel from the customer's power sources.
Ensure that the customer has properly disconnected the circuit breaker panel
from their power sources prior to continuing.
1. Switch off power to all CPU enclosures, devices, and drawers attached to the
circuit breaker panel. See the service guide for the CPU enclosure installed in
your rack, service guide for the system installed in your rack, and service guide
for the drawers installed in your rack for more information.
Note: Once the customer's power source is switched off, ensure that a tag or
label is positioned over the switch to indicate that the power source is
intended to remain switched off.
4-22 7014 Model S00 Rack Installation and Service Guide