Step 1540-18
1. Follow the instructions on the screen to select the system console.
2. When the DIAGNOSTIC OPERATING INSTRUCTIONS screen is displayed,
press Enter.
3. If the terminal type has not been defined, you must use the Initial Terminal option
on the FUNCTION SELECTION menu to initialize the AIX operating system
environment before you can continue with the diagnostics. This is a separate and
different operation than selecting the console.
4. Select Advanced Diagnostics Routines.
5. If the NEW RESOURCE screen displays, select an option from the bottom of the
screen.
Note: Adapters or devices that require supplemental media are not shown in
the new resource list. If the system has adapters or devices that require a
supplemental media, select option 1.
6. When the DIAGNOSTIC MODE SELECTION screen displays, press Enter.
7. Select All Resources (if you were sent here from “Step 1540-22” on page 2-54,
select the Adapter/Device you loaded from the supplemental media).
Did you get an SRN?
NO Go to “Step 1540-20” on page 2-54.
YES Go to “Step 1540-19” on page 2-53.