Table 3-1 (Page 22 of 26). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
40210014 1. A stopped fan detected.
2. Loss of a redundant fan and a sub-
sequent locked fan. (If the system
is running, refer to the AIX error log
to find out which fan is failing. If
the system is not running, refer to
the SP error log.)
1. Failing fan.
2. FMC card.
40210024 Loss of a redundant fan and a subse-
quent slow fan. (If the system is
running, refer to the AIX error log to
find out which fan is failing. If the
system is not running, refer to the SP
error log.)
1. Failing fan.
2. FMC card.
40210091 Loss of a redundant fan. (Refer to the
SP error log to find out which fan is
failing.)
1. Failing fan.
2. FMC card.
40211804 Failure to communicate with FMC. 1. Failing fan.
2. FMC card.
40A00000 System firmware IPL failure. 1. Surveillance mode control is from
the Service Processor (SP) Menus.
2. Verify that the system firmware
supports SP surveillance.
3. CPU card.
4. I/O board. (See notes on 3-1.)
5. Service processor.
6. If the problem persists, call the
support center for assistance.
40B00000 The operating system surveillance
interval exceeded.
1. Surveillance mode control is from
the Service Processor(SP) Menus.
2. Verify that the Operating System
(OS) Heartbeat Utility is installed
and has been activated.
3. Check for errors or unusual condi-
tions that might prevent the OS
from reporting Heartbeat mes-
sages; such as system dump,
machine check or checkstop error.
Review the error log.
4. I/O board. (See notes on 3-1.)
5. Service processor.
6. If the problem persists, call the
support center for assistance.
Chapter 3. Error Code to FRU Index 3-23