Step 2010-2
One of the following conditions exist. Take the action described.
1. You have an hdisk that has no associated pdisk.
a. Issue the system cfgmgr command.
b. Retry the Configuration Verification service aid.
c. If the problem remains, a software error has probably occurred. Call your
support center for assistance.
2. You have a pdisk that has no associated hdisk.
a. Run diagnostics (using system verification mode) to the pdisk.
b. If you get an SRN, go to Table 5-1 on page 5-3 and follow the actions
described.
If you do not get an SRN, the disk formatting may be incompatible with the
system (the disk was formatted on a different type of using system).
1. Format the pdisk.
2. Issue the system cfgmgr command.
3. Retry the Configuration Verification service aid.
3. If the problem remains, a software error has probably occurred. Call your
support center for assistance.
2-46
RS/6000 Enterprise Server Model H50 Installation and Service Guide