Firmware/POST Error Codes
If you replace FRUs and the problem is still not corrected, go to “MAP 1540:
Minimum Configuration” on page 2-25
If you replace FRUs and the problem is corrected, go to "MAP 410: Repair
Checkout" in the
Diagnostic Information for Multiple Bus Systems
Table 3-1 (Page 1 of 26). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
203w0xyz w=loop number
x=0 missing link
y=port number
z=c for interconnect z=b missing
link back z=E RIO de-configured
Check Cables, then Remote I/O.
20A80xxx Remote initial program load (RIPL)
error.
20A80000 Insufficient information to boot. Verify the IP address.
20A80001 Client IP address is already in use by
other network device.
Change IP address.
20A80002 Cannot get gateway IP address. Refer to “Checkpoints” on page 3-29
table using code E174.
20A80003 Cannot get server hardware address. Refer to “Checkpoints” on page 3-29
table using code E174.
20A80004 Bootp failed. Refer to “Checkpoints” on page 3-29
table using code E175.
20A80005 File transmission (TFTP) failed. Check network connection, try again.
20D00xxx Unknown/Unrecognized device
20D0000F Self-test failed on device, no
error/location code information avail-
able.
Check the System Management Ser-
vices error log entry (described in “Step
1020-4” on page 2-9) for this error
code. The location code (if present) in
the error log entry should identify the
location of the failing device.
20D00010 Self-test failed on device, can't locate
package.
Contact you service support represen-
tative for assistance.
20D00011 Cannot determine Machine Model. The Machine Model is part of the
System Vital Product Data. Perform
corrective actions listed for errors
2BA00050, 2BA00051.
20E00xxx Security
3-2 RS/6000 Enterprise Server Model H50 Installation and Service Guide