Exit XTSPTIN
When invoked
Before execution of a temporary storage interface request for a CICS
internal queue (for example, for interval control or BMS queues).
Exit-specific parameters
UEPTRANID
Address of the 4-byte transaction ID.
UEPUSER
Address of the 8-byte user ID.
UEPTERM
Address of the 4-byte terminal ID.
UEPPROG
Address of the 8-byte application program name.
UEP_TS_FUNCTION
Address of a byte containing the function:
v UEP_TS_FUN_PUT
v UEP_TS_FUN_PUT_REPLACE
v UEP_TS_FUN_GET
v UEP_TS_FUN_GET_SET
v UEP_TS_FUN_GET_RELEASE
v UEP_TS_FUN_GET_RELEASE_SET
v UEP_TS_FUN_RELEASE
UEP_TS_QUEUE_NAME
Address of a 16-byte field containing the queue name.
UEP_TS_DATA_P
Address of a fullword containing the address of the data. (Put and
put_replace).
UEP_TS_DATA_L
Address of a fullword containing the length of the data. (Put and
put_replace).
UEP_TS_STORAGE_TYPE
Address of a byte containing the storage type. (Put requests).
On input to the exit, the parameter will be set to either
UEP_TS_STORAGE_TYPE_MAIN or
UEP_TS_STORAGE_TYPE_AUX_TST. This parameter may be
modified by the exit to any of the values below.
Note that if CICS has been initialized with TS main-only support,
setting this parameter has no effect.
UEP_TS_STORAGE_TYPE_MAIN
Main storage.
UEP_TS_STORAGE_TYPE_AUX_TST
Auxiliary storage (recoverability determined by the TST).
UEP_TS_STORAGE_TYPE_AUX_RECOV_YES
Auxiliary storage (recoverable).
UEP_TS_STORAGE_TYPE_AUX_RECOV_NO
Auxiliary storage (non-recoverable).
210 Customization Guide