Step
1520-2
Check
the
circuit
breaker
for
the
drawer
that
does
not
have
power.
Is
the
circuit
breaker
tripped?
NO
Go
to
“Step
1520-7.”
YES
Reset
the
circuit
breaker
by
turning
the
circuit
breaker
off,
then
on.
Go
to
“Step
1520-3.”
Step
1520-3
Is
there
power
to
the
drawer?
NO
Check
the
circuit
breaker
again.
Go
to
“Step
1520-4.”
YES
Go
to
MAP
0410:
Repair
Checkout
in
the
Diagnostic
Information
for
Multiple
Bus
Systems.
Step
1520-4
Is
the
circuit
breaker
tripped
again?
NO
Go
to
“Step
1520-7.”
YES
Go
to
“Step
1520-5.”
Step
1520-5
1.
Set
the
circuit
breaker
to
the
off
position.
2.
Disconnect
the
power
cable
from
the
device’s
power
supply.
3.
Set
the
circuit
breaker
to
the
on
position.
Is
the
circuit
breaker
tripped
again?
NO
Replace
the
device
power
supply.
Go
to
MAP
0410:
Repair
Checkout
in
the
Diagnostic
Information
for
Multiple
Bus
Systems.
YES
Turn
circuit
breaker
off
and
replace
the
power
cable.
Set
the
circuit
breaker
to
the
on
position.
Go
to
“Step
1520-6.”
Step
1520-6
Did
the
circuit
breaker
trip
again?
NO
Go
to
MAP
0410:
Repair
Checkout
in
the
Diagnostic
Information
for
Multiple
Bus
Systems.
YES
Replace
the
circuit
breaker.
Go
to
MAP
0410:
Repair
Checkout
in
the
Diagnostic
Information
for
Multiple
Bus
Systems.
Step
1520-7
Is
there
power
to
the
drawer?
NO
Replace
the
device
power
supply.
Go
to
“Step
1520-8”
on
page
19.
YES
Go
to
MAP
0410:
Repair
Checkout
in
the
Diagnostic
Information
for
Multiple
Bus
Systems.
CAUTION:
Energy
hazard,
remove
power
before
servicing.
Disconnect
two
power
supply
cords.
C23
18
7014
Model
T00,
and
Model
T42
Service
Guide