7. Insert the DIMM into the connector by aligning the edges of the DIMM with the
slots at the ends of the DIMM connector. Firmly press the DIMM straight down
into the connector by applying pressure on both ends of the DIMM
simultaneously. The retaining clips snap into the locked position when the
DIMM is firmly seated in the connector. If there is a gap between the DIMM
and the retaining clips, the DIMM has not been correctly installed. Open the
retaining clips, remove the DIMM, and then reinsert it.
8. Reconnect any cables that were disconnected during removal.
9. Press the power-supply cage release tab and rotate the power-supply cage
assembly into the chassis until it locks in place.
10. Return the power-supply cage handle to the locked position.
11. If you have a hot-swap model, reinstall the hot-swap power supplies (see
“Installing a hot-swap power supply” on page 118).
12. Install the side cover (see “Installing the side cover” on page 101).
13. Lock the side cover.
14. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Chapter 4. Removing and replacing server components 121