--
Depending on room characteristics
Depending on water quality
Carried out by owner
Essential
Maintenance and cleaning procedures as well as problems derived from failing to carry them out
ARE NOT COVERED BY THE WARRANTY. Service personnel will invoice you for travel
expenses, time invested and materials required for maintenance and cleaning of unit.
8. MAINTENANCE AND CLEANING PROCEDURES
WARNING: Unit should always be disconnected during maintenance/cleaning procedures.
Water Condenser
1) Disconnect machine.
2) Close water faucet.
3) Disconnect water entry/exit from condenser.