ICE TECH SS / SK Technical Service
Manual
19
5. OPERATION
5.1. Preliminary check
a) Is machine levelled?
b) Are voltage and frequency of mains supply the same as indicated on rating plate?
c) Is drainage system working properly?
d) Is air circulation and room temperature adequate? (Air-cooled models)
AMBIENT TEMPERATURE WATER TEMPERATURE
MAXIMUM 40° C 35° C
MINIMUM 5° C 5° C
e) Is water pressure adequate?
MAXIMUM 0.7 Kg/cm2
MINIMUM 6 Kg/cm2
ATENTION: Check that voltage and mains frequency is the same as in the rating plate.
5.2. Starting up
Once preliminary check has been completed (ventilation, connections, temperature, etc.),
proceed as follows:
1) Open water faucet. Check for leaks.
2) Plug machine into electricity mains supply.
3)Push the (blue) switch found on the machina front side.
4) Ensure that there are no strange vibrations or scraping sounds
5) Check that the water curtain moves freely
6) Verify that spray nozzles are all working
7) After 10 minutes, check that the water bin has no leaks on the maximum level overflow.