ICON EDGE USER MANUAL
32
reset.
PRISM 1 wheel Er
(PRISM 1 wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The PRISM - movement is not located in the default position after the
reset.
Prism1Rot 1 wheel Er
(Prism1Rot wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The PRISM - movement is not located in the default position after the
reset.
PRISM 2 wheel Er
(PRISM 2 wheel- error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The PRISM - movement is not located in the default position after the
reset.
Prism1Rot 2 wheel Er
(Prism2 Rot wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The PRISM - movement is not located in the default position after the
reset.
FOCUS wheel Er
(FOCUS wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The FOCUS - movement is not located in the default position after the
reset.
ZOOM wheel Er
(ZOOM wheel_ error) This message will appear after the reset of the fixture if the head’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or its driving IC on
the main PCB). The FROST - movement is not located in the default position after the reset.
Frost wheel Er
(Frost wheel_ error) This message will appear after the reset of the fixture if the heads magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or its driving IC on
the main PCB). The FOCUS - movement is not located in the default position after the reset.
Animation wheel Er
(Animation wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The FOCUS - movement is not located in the default position after the
reset.