EasyManuals Logo

ICP C9MPT050F12C1 User Manual

ICP C9MPT050F12C1
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
8
440 04 2023 02
Specifications are subject to change without notice
TECHNICAL SUPPORT
Manufacturers Number (Mfr No --SeeRatingPlate)
ALL Models
Specifications
*9MPV050F12 *9MPV075F12 *9MPV100J20 *9MPV125L20
General
Gas Type
Nat Propane Nat Propane Nat Propane Nat Propane
Transformer Size (VA)
T’stat Heat Anticipator
40
.50
Input (Btuh) Std/Alt. HI Heat
LO Heat
Output (Btuh) Std/Alt. HI Heat
LO Heat
Temp. Rise (
o
F/
o
C) HI Heat
LO Heat
50,000
35,000
46,000
32,000
35--65/19--46
35--65/19--46
75,000
52,500
70,000
48,000
40--70/22--38
40--70/22--38
100,000
70,000
93,000
65,000
40--70/22--38
40--70/22--38
125,000
87,500
118,000
82,000
40--70/22--38
40--70/22--38
Electrical (Volts/Hz) 115/60 115/60 115/60 115/60
Rating Plate Amps 9.5 11.4 14.6 15.4
Gas & Ignition
Gas Type
Std. Main Orifices (No/Size)
Gas Valve Honeywell
Regulation Type
Manifold Press. HI Heat (in wc)
LO Heat (in wc)
Nat.
2/42
VR8205Q
SNAP
3.5
1.7
Propane
2/54
VR8205Q
SNAP
10.0
4.9
Nat.
3/42
VR8205Q
SNAP
3.5
1.7
Propane
3/54
VR8205Q
SNAP
10.0
4.9
Nat.
4/42
VR8205Q
SNAP
3.5
1.7
Propane
4/54
VR8205Q
SNAP
10.0
4.9
Nat.
5/42
VR8205Q
SNAP
3.5
1.7
Propane
5/54
VR8205Q
SNAP
10.0
4.9
Ignition Type
Hot Surface
Combustion
Flue Outlet Size (Inches)
Std. Outlet Temp (less than)
Comb. Blower (MFD/Volts)
2
140
o
F/60
o
C
4/370
2
140
o
F/60
o
C
4/370
3
140
o
F/60
o
C
4/370
3
140
o
F/60
o
C
4/370
@Blower/ @ Transition Box (HI Heat)
Std. Pressures (in wc)
5 No Elbows
40 +5--90° DWV Elbows
@Blower/ @ Transition Box (LO Heat)
Std. Pressures (in wc)
5 No Elbows
40 +5--90° DWV Elbows
--1.80 / --2.60
--1.30 / --2.30
--1.20 / --1.90
--1.00 / --1.80
--1.80 / --2.60
--1.30 / --2.30
--1.20 / --1.90
--1.00 / --1.80
--1.80 / --2.60
--1.70 / --2.50
--1.20 / --1.90
--1.00 / --1.80
--1.80 / --2.60
--1.70 / --2.50
--1.30 / --2.30
--1.20 / --2.20
Limits & Controls
Rollout Switch (
o
F/
o
C)
Limit Control Setting (
o
F/
o
C)
300/149
260/127
300/149
210/99
300/149
240/116
300/149
190/88
Furnace Control (Type)
Furnace Control On
(Timed--secs) Off
Integrated
30 HI /45 LO
60,100,140,180
Std. Pressure Sw. (Part No)
(HI Heat)Blwer Switch Press (Close)
Blower Switch Pressure (Open)
(LO Heat)Trans Switch Press (Close)
Transition Switch Pressure (Open)
1013515
0.95
0.80
1.70
1.50
1013515
0.95
0.80
1.70
1.50
1013515
0.95
0.80
1.70
1.50
1013166
1.30
1.10
1.80
1.60
High Altitude Pressure Sw. (Part No)
(HI Heat)Blwer Switch Press (Close)
Blower Switch Pressure (Open)
(LO Heat)Trans Switch Press (Close)
Transition Switch Pressure (Open)
1013165
0.70
0.55
1.40
1.20
1013165
0.70
0.55
1.40
1.20
1013165
0.70
0.55
1.40
1.20
1013157
0.85
0.70
1.70
1.50
Blower Data
Wheel Size (D x W inches)
FLA Motor Amps/Max RPM
Motor T ype/H.P.
Filter Type & Size (qty.) Permanent -- supplied
Min. Cool Cap. (Tons)
Max. Cool Cap. (Tons)
11 x 8
7.7/1240
ECM/
1
/
2
16x25x1
1.5
3
11 x 10
9.6/1240
ECM/
3
/
4
16x25x1
1.5
3
11 x 10
12.8/1240
ECM/1
16x25x1 (2)
2
5
11 x 10
12.8/1240
ECM/1
16x25x1 (2)
2
5
Gas Conversion Kits All Models
Nat to Propane NAHA002LP (1172959*)
Propane to Nat NAHA002NG (1172961*)
*Order from Service Parts

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ICP C9MPT050F12C1 and is the answer not in the manual?

ICP C9MPT050F12C1 Specifications

General IconGeneral
BrandICP
ModelC9MPT050F12C1
CategoryFurnace
LanguageEnglish

Related product manuals