Explains the meaning of each character in the model number, including brand, series, and features.
Step-by-step guide to test electrical grounding and polarity using ohm and voltmeters.
Methods to verify and adjust the furnace's gas firing rate for proper operation.
Table of acceptable temperature rise ranges for different furnace models.
Guidelines for optimal thermostat placement for accurate temperature control.
Purpose and adjustment of heat anticipators in thermostats for temperature stability.
Method for measuring current draw to set heat anticipators accurately.
Description of the normally closed switch monitoring supply air temperature.
Explains manual reset type roll out switches used with Honeywell ST9160.
Description of the auxiliary limit switch monitoring return air temperature.
Information on pressure switches required for high altitude installations.
Causes for lower than normal negative pressures at the combustion blower.
Causes for higher than normal negative pressures at the combustion blower.
Guidelines for standard rooftop and sidewall vent terminations.
Charts detailing pipe diameter requirements for various vent configurations.
Specific piping charts for dual certified, non-direct vent models.
Piping charts for direct vent installations across all series.
Venting table for specific concentric termination kits and dual piping.
Explanation of how to set the heating fan OFF delay using DIP switches.
Normal operating sequence for the SV9541M Smart Valve control.
Initial state and thermostat call for heat sequence in flowchart.
Waiting condition for pressure switches to open in flowchart.
Combustion blower operation and pre-purge sequence in flowchart.
Trial for ignition sequence and pilot light verification in flowchart.
Condition for loss of flame during operation and recycling in flowchart.
Sequence when the call for heat terminates in flowchart.
Criteria and methods for selecting blower speeds for heating and cooling.
Procedure for selecting heating blower speed based on temperature rise.
Procedure for selecting cooling blower speed based on A/C coil requirements.
Instructions for changing blower motor speed taps.
Detailed steps for removing and reinstalling the secondary heat exchanger.
Detailed steps for removing and reinstalling the primary heat exchanger.
Table correlating LED status codes with system indications.
Descriptions of what different system indications mean.
Recommended checks and repairs for identified issues.
Correlation of LED status codes with system indications.
Descriptions of system indications.
Recommended checks and repairs for identified issues.
General model information including gas type, transformer size, and T'stat anticipator.
Details on gas valve, regulation type, and ignition series.
Information on fan control type and timing.
Part numbers for gas conversion kits.
General model information including input, output, and electrical ratings.
Gas type, valve, regulation, and ignition details for N9MP1 series.
Flue outlet size and standard outlet temperature data.
Pressure specifications for blower and transition box.
Settings and part numbers for limit and pressure switches.
Specifications for blower type, motor, and capacitor.
Part numbers for gas conversion kits.
General model information including input, output, and electrical ratings.
Gas type, valve, regulation, and ignition details for N9MP1 (A2) series.
Flue outlet size and standard outlet temperature data.
Pressure specifications for blower and transition box.
Settings and part numbers for limit and pressure switches.
Specifications for blower type, motor, and capacitor.
General model information including input, output, and electrical ratings.
Gas type, valve, regulation, and ignition details for *9MPD (A2) series.
Flue outlet size and standard outlet temperature data.
Pressure specifications for blower and transition box.
Settings and part numbers for limit and pressure switches.
Specifications for blower type, motor, and capacitor.
Blower performance data (CFM) for 50 Mbtu models at various static pressures.
Blower performance data (CFM) for 75 Mbtu models at various static pressures.
Blower performance data (CFM) for 100 Mbtu models at various static pressures.
Blower performance data (CFM) for 100 Mbtu models at various static pressures.
Blower performance data (CFM) for 125 Mbtu models at various static pressures.