Construction Manual
K2-915-CAP07
Fuel system
Issue 00/Rev.01 28 May 2019
1
Collegamento pompe elettriche / Connection electric pump
Installare la scatola pompe, in dotazione, forando la paratia sinistra ( vista pilota) in modo tale che
non vengano danneggiati gli angolari di irrobustimento.
Figura 1
Avvitare la scatole pompe alla paratia.
Collegare pompe elettriche ai connettori dedicati e successivamente collegare fuel pump A su
main e fuel pump B sull’aux nel pannello.
Figura 2
Question and Answer IconNeed help?

Do you have a question about the ICP VENTURA and is the answer not in the manual?

ICP VENTURA Specifications

General IconGeneral
Seats2
EngineRotax 912ULS
ManufacturerICP
TypeLight aircraft
Power100 hp
Length6.40 m (21 ft 0 in)
Stall Speed40 mph

Summary

Electric Pump Installation and Connection

Pump Box Mounting and Securing

Install and secure the pump box to the left bulkhead, avoiding reinforcement angles.

Electric Pump and Fuel Line Connections

Connect electric pumps to panel connectors and fuel lines to the pump box IN/OUT fittings.

Fuel System Schematics and Components

Fuel System Schematic Overview

Diagram illustrating the overall fuel system layout with component connections and lines.

System Component Integration Diagram

Diagram showing firewall integration, pumps, filters, regulator, and injectors in the fuel system.

Pressure Sensor and Airbox Connection

Pressure Sensor Wiring

Connect the pressure sensor to the electrical system and Airbox via UM243 fitting.

Non-Return Valve Installation

Non-Return Valve Placement

Install the non-return valve near the connector tank on the fuel return line.