ID TECH EzWriter
READ DATA Example
HOST
Direction
Reader/Writer
Command
code:<ESC>r
HEX code: 1B, 72
(read command)
(status ACK)
(Wait until swipe card)
Command ACK:
<ESC>s<ESC> 01,%01?<ESC> 02,
23?<ESC> 03, 45??<FS><ESC>
<status>
HEX code:
1B, 73, 1B, 01, 25, 30, 31, 3F, 1B, 02,
3B, 32, 33, 3F, 1B, 03, 3B, 34, 35, 3F,
3F, 1C, 1B, status
Status= 30, No Error
Status= 31, Track 1 Read Error
Status= 32, Track 2 Read Error
Status= 33, Track 1, 2 Read Error
Status= 34, Track 3 Read Error
Status= 35, Track 1, 3 Read Error
Status= 36, Track 2, 3 Read Error
Status= 37, Track 1, 2, 3 Read Error
Status= 38, Read after write timeout