FC6A S
ERIES
MICROS
MART
U
SER
S
M
ANUAL
FC9Y-B1722 5-51
5: F
UNCTIONS
AND
S
ETTINGS
Forced I/O List
The forced I/O function is controlled with the Force I/O List in WindLDR.
(1) New
Register an I/O device to the list that will be set for forced I/O.
(2) Force On
Switches the status to on.
(3) Force Off
Switches the status to off.
(4) Force Release
Cancels the status of the I/O device set for forced I/O.
(5) Refresh
Updates the list.
(6) Start/Suspend Force
Starts and stops the forced I/O function.
Start/Suspend Force
New
Force ON
Force OFF Refresh
Force Release