2
POWER SUPPLY
DESCRIPTION
MODEL
DOM-12 / DOM-12 PH /
DOM-12 PLUS
DOM-24 / DOM-24 PH /
DOM-24 PLUS
DOM-32 / DOM-32 PH /
DOM-32 PLUS
DOM-42 / DOM-42 PH /
DOM-42 PLUS
Standard working voltage 230 V AC, 50
/
60 Hz.
Output (dc) 12 A (2x6 A) 24 A (2x12 A) 32 A (2x16A) 42 A (6x7A)
Production (g/h) 10 - 12 20 -24 25 - 32 34 - 42
Swimming pool (m
3
)
Warm: 16 – 24°C (60,8 – 75,2 °F)
Hot: +25°C (77 °F)
60
50
100
80
160
120
200
160
Flow detector Gas detector
Salinity /Temperature range 3 – 12 g./l. / +15 - 40
o
C (59 – 104
o
F)
Electrodes
SELF-CLEANING coated Titanium
Estimated lifetime: 4.000 – 7.000 hours of operation
Production control 0 – 100 % ( 11 production levels)
Cover control
Input for potential free contact
Programmable reduction of production from control panel when cover is closed [10% ... 90%]
Polarity switch Programmable from control panel: 2/3 hours + test mode
External control
Two inputs for potential free contact for external flow detector and ORP/RESIDUAL CHLORINE control.
Programmable contact logics from unit control panel
Salt level protection
A
utomatic production protection
ELECTROLYSIS CELL
DESCRIPTION
MODEL
DOM-12 / DOM-12 PH /
DOM-12 PLUS
DOM-24 / DOM-24 PH /
DOM-24 PLUS
DOM-32 / DOM-32 PH /
DOM-32 PLUS
DOM-42 / DOM-42 PH /
DOM-42 PLUS
Minimum recirculation flow 2 m
3
/h 4 m
3
/
h6 m
3
/
h 8 m
3
/
h
Electrode number 5 7 7 13
Material Methacrylate derivate
Pipe connections Gluing with PVC adhesive Ø 63 mm
Max. Recommended pressure 1 Kg./cm
2
Working temperature Less than 40
o
C (104°F)
PH / ORP CONTROL
DESCRIPTION
MODEL
DOM-12 PH
DOM-12 PLUS
DOM-24 PH
DOM-24 PLUS
DOM-32 PH
DOM-32 PLUS
DOM-42 PH
DOM-42 PLUS
Measure range 0.0 – 9.9 (pH)
/
0 – 999 mV (ORP)
Control range 7.0 – 7.8 (pH)
600 - 850 mV (ORP)
Precision ± 0.1 pH
/
± 1 mV
Calibration
A
utomatic, with calibration solutions
Control output [pH] One output 230 V
A
C
/
500 mA for dosage pump connection
pH / ORP sensor
Epoxy body, 12x150 mm., 0-80
o
C (32 – 176°F)
blue, range 0 – 12 (pH),
red, range 0 – 1000 mV (ORP)

Related product manuals