Preparation of the machine (first phase)
Switch on the machine with the door closed.
Close completely the basket plates.
Open the door and switch off the machine.
Clean using a cloth the old lubricant and the possible residual paint (See paragraph
12.3)
Greasing (first phase)
Grease the vertical guides using a
brush.
Grease the plates command
screws.
Grease the shaft
Preparation of the machine (second phase)
Close the door and switch on the machine
Open completely the basket plates
Open the door and switch off the machine.
Now it is available the central part of the basket that previously is covered by the
guides.
Clean using a cloth the old lubricant and the residual paint
(See paragraph 12.3)
Greasing (second phase)
Repeat the greasing operation for the part of the guides, screws and shaft that
now are discovered.
Alternative operation
It is possible to use spray grease too, but
it has to be thick and adhesive