M
Michael MyersJul 26, 2025
What to do if my Idex FAST & FLUID Galileo displays E-3 ERROR 3?
- BBrad FinleyJul 26, 2025
If your Idex Mixer displays E-3 ERROR 3, try the following: * Increase the distance pressing the key “D” before beginning. * Regulate or replace the belt. * Clean the PCB3 board sensor. * Push the “STOP” key before starting the mixing cycle. * Check for a Loosen/broken belt for closing plates. * Check for a Defective cable between Logic board and Optical sensors. * Examine the sensor for closing (on optical sensors board) for damage. * Inspect the Optical sensors board for defects.