TROUBLESHOOTING CHART
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED
inc.
PART NO. 70 - 5105 G471PL (Rev A)
8
Low High Pump Motor Excess Reason and remedy
Vacuum Pressure Vacuum Pressure Overheat Overload Noise for problem.
At Pump Filter dirty. Clean or replace.
At pump Muffler dirty. Clean or replace.
Valves dirty or valves bent.
Clean or replace.
Worn diaphragm.
Repair or replace.
Relief valve set too high.
Inspect and adjust.
Relief valve set too low.
Inspect and adjust.
At pump At pump Plugged vacuum/pressure line.
Inspect and repair.
At pump Collapsed vacuum line.
Inspect and repair.
Low voltage, won’t start.
Check power source.
Voltage wrong.
Check power source.
Worn diaphragm.
Replace.
Leaky hose or check valve.
Replace.
Dirt or liquid on top of diaphragm.
Inspect and clean.
Motor not wired correctly.
Check wiring diagram/line voltage.